GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Main Functions
- 36 -
OUTPUT LINE RESPONSE TIME
Opt In Filter Selector Function
As for the surge protection of the optical input, the filter can be selected from 5 steps which are 10 μs
(Typical), 100 μs, 500 μs, 1 ms and 10 ms. If the filter is set, a pulse with a shorter width than the filter
setting value cannot be accepted.
Pulse Generator
Tips for using the Pulse Generator
This camera has a frequency divider using the pixel clock as the basic clock and one pulse generator.
In the Pulse Generator, various Clear settings are connected to GPIO. The following shows the Pulse
Generator default settings.
Note:
When Pulse Generator Repeat Count is set to “0”, the camera is operating in free-running
mode. However, based on the default settings, Length=1, Start Point=0 and End Point=1, Pulse
Generator stops at High output. Therefore, if Start Point=0 and End Point=1 are configured,
Length should be “2” as the minimum active width.
Clock Pre-scaler
Clock pre-scaler (Divide Value) can set the dividing value of the frequency divider (12-bit length) and
the pixel clock is used for this. On this camera, the pixel clock is set at 48MHz.