GO-5000M-PGE | GO-5000M-PGE-UV | User Manual (Ver. 2.0)
Main Functions
- 40 -
Pulse Generator Setting Table
Display Name
Value
Clock Pre-scaler
1 to 4096
Pulse Generator Clock (MHZ)
[Pixel Clock:48 MHz]÷[Clock Pre-scaler]
Pulse Generator Selector
Pulse Generator 0
- Pulse Generator Length
1 to 1048575
- Pulse Generator Length (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator Length]
- Pulse Generator Frequency (Hz)
[ Pulse Generator Length (ms)]
-1
- Pulse Generator Start Point
0 to 1048574
- Pulse Generator Start Point (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator Start Point]
- Pulse Generator End Point
1 to 1048575
- Pulse Generator End Point (ms)
([Clock Source]÷[Clock Pre-scaler])
-1
x [Pulse Generator End Point]
- Pulse Generator pulse-width (ms)
[ Pulse Generator End Point (ms)] - [ Pulse Generator Start Point (ms)]
- Pulse Generator Repeat Count
0 to 255
- Pulse Generator Clear Activation
Clear Mode for the Pulse Generators
FreeRun
High Level
Low level
Rising Edge
Falling Edge
- Pulse Generator Clear Sync Mode
Async mode
Sync mode