CV-M9 GE
- 36 -
8.6.
Operation Mode and Functions matrix
ID
(Value)
Mode
Shutter
Preset /
Program.
Binning
Partial
Scanning
Smear-
less
LVAL
Sync/Async
Auto Iris
output
0x00 Continuous Yes
Yes
Yes
No
Not
applicable
Yes
Note 2.
0x01
Edge Pre-
select
(EPS)
Yes Yes Yes Yes Yes No
0x02
Pulse Width
Control
(PWC)
Not
applicable
Yes Yes Yes
Yes
No
0x09
Sequential
Edge Pre-
select
Yes Yes Yes Yes Yes No
0x11
EPS
Delayed
Readout
Yes Yes Yes Yes Yes No
0x12
PWC
Delayed
Readout
Not
applicable
Yes Yes Yes
Yes
No
Write ID in register address 0xA040 in order to set trigger mode.
Note 1: Before switching between trigger modes ID 0x09 through 0x12, first set to “ID- 00x0,
Continuous mode” and then set “Video Sending Flag - Register 0xA44C" to OFF.
Note 2: In partial scan mode Auto Iris output is available, but Auto Exposure is not available.
Note 3: When using trigger modes in combination with Smear-less readout, only
LVAL-synchronous accumulation is active.
Note 4: In PWC trigger mode, do not use LVAL a-synchronous accumulation if the trigger pulse
has a pulse width exceeding 3 frames.