![JAI BM-500 GE User Manual Download Page 15](http://html1.mh-extra.com/html/jai/bm-500-ge/bm-500-ge_user-manual_3231899015.webp)
BM-500GE / BB-500GE
15
The pulse generator o creates 4 ms pulse.
The following shows JAI SDK Camera Control Tool for setting Pulse Generator.
6.2
Opto-isolated Inputs/Outputs
The control interface of the C3 GigE Vision camera series has opto-isolated inputs and outputs,
providing galvanic separation between the camera's inputs/outputs and peripheral equipment.
In addition to galvanic separation, the opto-isolated inputs and outputs can cope with a wide
range of voltages; the voltage range for inputs is +3.3V to +24V DC whereas outputs will
5V to +24V DC.
Fig.9. Photo coupler