background image

 
 
 

 

 
 

 

 

 
 
 

 

BM-500

 

GE 

BB-500

 

GE 

BB-500GE-S

 

Digital Monochrome / Color 

Progressive Scan GigE Vision Camera

 

 

 
 
 

 
 

 Document Version: 2.3 

BMB-500GE_Ver.2.3_Mar2017 

 

 

User's Manual 

Summary of Contents for BM-500 GE

Page 1: ...BM 500GE BB 500GE BB 500GE S Digital Monochrome Color Progressive Scan GigE Vision Camera Document Version 2 3 BMB 500GE_Ver 2 3_Mar2017 User s Manual...

Page 2: ...to interface with the external strobe light The following drawing shows the typical connection with the strobe light Fig 1 Except the mentioned subject the BB 500GE S is the same as the BB 500GE Pin n...

Page 3: ...uipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful...

Page 4: ...ace Specifications 17 6 3 Inputs and outputs table 17 6 4 Configuring the GPIO module 18 6 4 1 Input Output Signal Selector 18 6 5 GPIO programming examples 18 6 5 1 Pulse generator setting screen 18...

Page 5: ...ansfer for multiple cameras 36 8 4 3 1 If delayed readout is not used in continuous mode 36 8 4 3 2 If delayed readout is not used in trigger mode 36 8 4 3 3 If delayed readout is used 37 9 Basic Func...

Page 6: ...ze 59 11 4 4 Acquisition of the image 59 11 4 5 How to look at XML file 60 11 4 6 Feature Tree Information 60 11 4 7 Feature Properties Guru 61 12 External Appearance and Dimensions 65 13 Specificatio...

Page 7: ...tion The purpose of the GenICam standard is to provide a common program interface for various machine vision cameras By using GenICam cameras from different manufactures can seamlessly connect in one...

Page 8: ...or performing this function in the host PC The BM 500GE BB 500GE also complies with the GenICam standards as it has an internal XML file that is used to describe the functions features of the camera F...

Page 9: ...ms in Full Frame scan GPIO in combination with Pulse width trigger for more precise exposure time Sequencer trigger mode for on the fly change of gain exposure and ROI Edge Pre select and Pulse width...

Page 10: ...45 thumbscrews Horizontal type left and right of RJ 45 Note 2 Mounting holes M3 depth 5 mm for tripod mount plate Note 3 1 Note Rear protrusion on C mount lens must be less than 10 0mm 2 Note When an...

Page 11: ...camera Fig 3 12 pin connector 5 2 Digital Output Connector for Gigabit Ethernet Type RJ 45 HFJ11 1G02E L21RL or equivalent The digital output signals follow the Gigabit Ethernet interface using RJ 45...

Page 12: ...IN 1 75ohm Terminator 1 4 O TTL Out 1 5 GND 6 NC 7 NC 8 O TTL Out 2 9 GND 1 5 6 9 SW601 For selection of OPT IN and Iris Video OUT Factory default is UP position OPT IN To select an Iris video these...

Page 13: ...tween inputs counters and outputs is governed by internal register set up Fig 7 GPIO interface In the BM 500GE and BB 500GE the relation for the external interface is fixed as below Line Signal Connec...

Page 14: ...pixel clock for BM 500GE BB 500GE is 60 MHz 6 1 3 Pulse Generators 0 to 1 Each pulse generator consists of a 19 bit counter The behavior of these signals is defined by their pulse width start point an...

Page 15: ...face of the C3 GigE Vision camera series has opto isolated inputs and outputs providing galvanic separation between the camera s inputs outputs and peripheral equipment In addition to galvanic separat...

Page 16: ...t Circuit OPT OUT 1 and 2 3 3V t o 24 V U s er P ower 1 2 3 4 5 PS 810 1 2 3 2S C 409 8 2k 2 1 3 2 02 C Z 2 0Z 120 10 k B 3k 3 hiros e 12 c onne c tor hiros e 12 c onne c tor Use r sid e JAI C3_Series...

Page 17: ...Reset Pulse Generator 0 Pulse Generator 1 Input Ports LVAL IN DVAL IN FVAL IN EEN IN GPIO Port In 1 OPT IN 1 GPIO Port In 2 OPT IN 2 GPIO Port In 3 TTL IN GPIO Port In 4 LVDS IN Soft Trigger 0 Soft Tr...

Page 18: ...6 4 Configuring the GPIO module 6 4 1 Input Output Signal Selector The following shows JAI SDK Camera Control Tool for setting Line Selector Line Source 6 5 GPIO programming examples 6 5 1 Pulse gene...

Page 19: ...BM 500GE BB 500GE 19...

Page 20: ...Acquisition and Trigger Control JAI Exposure Mode Pulse width control Pulse Generators Pulse Generator selector Pulse Generator 0 Selector Line 5 OPT IN 1 Clock Choice 1 Pixel Clock 30MHz Counter Divi...

Reviews: