Setting range
Default value
Description
Configure settings for Multi ROI.
0: Off,
1: On
Off
Enable/disable Multi Roi.
0 〜 7
0 〜 7
Select the index for the Multi Roi mode.
MultiRoiWidth
ー
ー
Set the width for the selected Multi Roi index.
MultiRoiHeight
ー
ー
Set the height for the selected Multi Roi index.
MultiRoiOffsetX
ー
ー
Set the horizontal offset for the selected Multi Roi index.
MultiRoiOffsetY
ー
ー
Set the vertical offset for the selected Multi Roi index.
1 〜 8
ー
Set the maximum number of valid horizontal index numbers.
1 〜 8
ー
Set the maximum number of valid vertical index numbers.
Configure image capture settings.
0:SingleFrame,
1:MultiFrame,
2:Continuous
Countinuous
Select the image capture mode.
ー
ー
Start image capture.
ー
ー
Stop image capture.
1〜65535
1
In [MultiFrame] mode, set the number of frames to capture.
0.125〜
Display the frame rate as a frequency. (unit: Hz)
The maximum value varies depending on the PixelFormat setting and the
ROI setting.
0:AcquisitionStart,
1:AcquisitionEnd,
3:FrameStart
AcquisitionStart
Select the trigger operation.
TriggerMode
0:Off,
1:On
Off
Select the trigger mode.
TriggerSoftware
ー
ー
Execute the software trigger.
TriggerSource
ー
ー
Select the trigger signal source.
[Setting range]
7: PulseGenerator0, 8: PulseGenerator1, 9: PulseGenerator2
10: PulseGenerator3, 11: UserOutput0, 12: UserOutput1
13: UserOutput2, 14: UserOutput3,
19: Software,
23: Line4,
24: Line5
25: Line6,
29: Line10,
36: Nand0Out
37: Nand1Out
TriggerActivation
1:RisingEdge
2:FallingEdge
3:LevelHigh
4:LevelLow
RisingEdge
Select the polarity of the trigger signal
(i.e., location of signal at which trigger is applied).
TriggerOverlap
1:ReadOut
ReadOut
Select the trigger overlap operation. (ReadOut fixed)
TriggerDelay
0〜500000
0
Set the time of exposure start from trigger input. (unit: μs)
0: Off,
1: Timed,
2: TriggerWidth
Timed
Select the exposure mode.
Common,
Individual
Comon
When set to Individual, ExposureTime can be adjusted for
RGB individually.
Common,
Red, Green, Blue
Common
1μs 〜
ー
Set the exposure time. (μs)
The specifiable range varies depending on the [AcquisitionFrameRate]
setting.
The actual exposure time is the set value plus the image sensor offset 13.7
μs.
0: Off,
1: Once,
2: Continuous
Off
Set whether to enable auto exposure.
0: Off,
1: RCT
Off
Set whether to enable RCT mode.
AcquisitionFrameCount
AcquisitionStop
AcquisitionStart
AcquisitionMode
ExposureTime
ExposureMode
ExposureModeOption
TriggerSelector
MultiROIControl
AcquisitionControl
Item
AcquisitionFrameRate
ExposureAuto
MultiRoiVerticalEnableNumber
MultiRoiIndex
MultiRoiMode
MultiRoiHorizontalEnableNumber
ExposureTimeMode
ExposureTimeSelector
—
5
8
—
AP-3200T-10GE