Command Sequencer Mode
As with TriggerSequencer mode, you can define up to 128 indexes beforehand in this mode. Set
SequencerCommandIndex to point to one of your pre-configured indexes. This index will be executed
on each trigger, until it is changed to point to a different index, typically by your vision application. In
this way, Command Sequencer mode allows you to programmatically adjust your sequence in
response to image analysis or input from other sensors.
The same index table will be executed for subsequent triggers unless the CommandSequencerIndex
value is changed.
SequencerFrameNumber and SequencerSetNext cannot be used in CommandSequencer mode.
Notes:
l
The same index table will be executed for subsequent triggers unless the
CommandSequencerIndex value is changed.