AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Main Functions
- 70 -
Sequencer Function
Related Setting Items:
The Sequencer function lets you define up to 128 index combinations of exposure time, gain, ROI, and
other settings which can be stepped through each time a trigger is received. This is particularly useful
for quickly capturing multiple exposures of objects under inspection to adjust for areas or components
with significantly different levels of reflectance. You can specify the next index in the stepping
sequence and the order in which indexes are executed. Multiple indexes can also be executed
repeatedly.
Two operation modes (TriggerSequencer mode and CommandSequencer mode) are available for the
Sequencer function.
Note:
The Sequencer function cannot be used together with Sensor Multi ROI function.
About indexes (imaging conditions)
Up to 128 indexes can be configured. The following settings can be configured for each index.
However, SequencerFrameNumber and SequencerSetNext can only be configured in
TriggerSequencer mode.
Note:
For more information on each setting item, see
Item
Trigger Sequenceer Mode
Command Sequenceer Mode
SequencerFrameNumber
✓
SequencerSetNext
✓
SequencerWidth
✓
✓
SequencerHeight
✓
✓
SequencerOffsetX
✓
✓
SequencerOffsetY
✓
✓
SequencerGainAnalogAll
✓
✓
SequencerGainAnalogRed
✓
✓
SequencerGainAnalogGreen
✓
✓
SequencerGainAnalogBlue
✓
✓
SequencerExposureTimeCommon
✓
✓
SequencerExposureTimeRed
✓
✓
SequencerExposureTimeGreen
✓
✓
SequencerExposureTimeBlue
✓
✓
SequencerBinningHorizontal
✓
✓
SequencerBinningVertical
✓
✓
SequencerLUTEnable
✓
✓
SequencerBlackLevelDigitalAll
✓
✓