AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Main Functions
- 45 -
Shortest Repetition Period for Triggers
The reciprocal of the maximum frame rate is the time required to output one frame. The shortest
repetition periods for triggers cannot be lower than that value.
AP-1600T-PMCL
CameraLink ClockFrequency
Shortest Period of Trigger
Base
Medium
Medium
Medium
Ful
EightyBit
RGB8
RGB8
RGB10
RGB12
RGB8
RGB8
37.125MHz
44.5ms
22.3ms
44.5ms
44.5ms
16.8ms
13.4ms
74.25 MHz
22.3ms
11.2ms
22.3ms
22.3ms
8.4ms
7.9ms
84.86 MHz
19.5ms
9.8ms
19.5ms
19.5ms
7.9ms
7.9ms
AP-3200T-PMCL
CameraLink ClockFrequency
Shortest Period of Trigger
Base
Medium
Medium
Medium
Ful
EightyBit
RGB8
RGB8
RGB10
RGB12
RGB8
RGB8
37.125MHz
87.9ms
44.0ms
87.9ms
87.9ms
33.1ms
26.5ms
74.25 MHz
44.0ms
22.0ms
44.0ms
44.0ms
18.0ms
18.0ms
84.86 MHz
38.5ms
19.3ms
38.5ms
38.5ms
18.0ms
18.0ms
The above table indicates the shortest trigger periods for when
TriggerOverLap
is set to
Readout
.
When
TriggerOverLap
is set to
Off
, the exposure time is added to the period.
Minimum trigger pulse width
l
Camera Link : 3 μs
l
TTL In: 50 ns