AP-1600T-PMCL | AP-3200T-PMCL | User Manual (Ver. 2.0)
Miscellaneous
- 137 -
Item
Description
Blemish correction
Detection
Detect white blemishes using threshhold values (100 steps available)
(black blemish correction performed only at factory)
Correction
Interpolation using adjacent pixels (continuous blemishes not corrected)
Correctable pixels
200 pixels per sensor
ALC
Can be adjusted automatically together with AGC and auto exposure control
Gamma
0.45, 0.5, 0.55, 0.6, 0.65, 0.75, 0.8, 0.9, 1.0 (9 steps available)
LUT
OFF: γ = 1.0, ON = 257 points can be set
Vibration resistance
3G (20 Hz ~ 200 Hz X-Y-Z direction)
Impact resistance
50G
Power supply
12-pin
connector
Input range
DC + 12 V ~ + 24 V ± 10% (via input terminal)
Consumption
6.0 W (typ.) (default settings, 25 °C ambient temp., 12 V DC input)
7.6 W (max.)
PoCL
Input range
DC +10 ~ + 13V
Consumption
6.0 W (typ.) (default settings, 25 °C ambient temp., 12 V DC input)
7.4 W (max.)
Lens mount
C-mount: Lens mount protrusion length of 4 mm or less is supported
Flange back
17.526, tolerance: 0 mm to -0.05 m
Optical filter
IR cut filter
Verified performance temperature /
humidity
−5°C to +45°C* / 20% to 80% (non-condensing)
Storage temperature / humidity
−25°C to +60°C / 20% to 80% (non-condensing)
Regulations
CE (EN61000-6-2 and EN61000-6-3), FCC part 15 class B, RoHS, WEEE
Dimensions (housing)
44 × 44 × 74 mm (WHD) (excluding mount protrusions)
Weight
170 g
Notes:
l
Approximately 30 minutes of warm-up are required to achieve these specifications.
l
Design and specifications are subject to change without notice.
Cautions
:
About the verified performance temperature
Make sure the following temperature conditions are met when operating the unit.
l
The camera's internal temperature sensor detects temperatures of 72°C or less during
operation.
l
The top surface of the camera's casing is 57°C or less.
If the above temperature conditions are exceeded, take measures to dissipate heat according to
your installation environment and conditions.