46
6. OPERATION
6.1. STANDARD - DPC.VE45
[4]
N
L
230V - 50Hz
GND
Power Supply
Input: 110-240V - 50/60 Hz
Output: 12V
12 V
Optie
The unit starts at the last selected speed(1, 2 or 3), as soon as the water temperature > 28 ̊C.
The unit starts at the last selected speed(1, 2 or 3), as soon as the water temperature < 24 ̊C.
Off
All functions are disabled until the user switches on the unit via the control panel.
3 speeds .
Off
The user manually selects the
desired mode via the control
panel The unit can run at 3
speeds. The unit starts as
soon as the set water tempe-
rature has been reached.
6.1.1. Control
Press the button until the desired mode is reached
(± 3 sec.).
Red LEDs
are flashing in the set mode: the water
temperature of the supplied water is too low (Tw <
28 ̊C).
Blue LEDs
are flashing in the set mode: the water tempe-
rature of the supplied water is too high (Tw > 24 ̊C).
3”
3”
3”
verwarmen
koelen
Manually raising / lowering the fan speed :
1
2
MODE
3
1
2
MODE
3
1
2
MODE
3
Speed : 1
Speed : 2
Speed : 3