11
■
The installation of electrical devices and equipment (sockets,
switches, etc.) in the bathroom must be in compliance with legal
standards and regulations in the country where the appliance is
installed.
■
To connect the building’s electrical system, you must use a
cable protected with a sheath with characteristics not inferior to
H 07 RN-F
and with a suitable cross section
(220-240 V ~: min.
6 mm2; 380-415 V 2-3N ~: min. 2.5 mm
2
).
D
The building’s electrical system must be equipped
with a 0.03 A differential switch.
■
In order to carry out the equipotential connection as specified
in the specific national standards, the installer must use the ter-
minals provided on the frame of the
“shower”
module and on
the
“hammam”
module, identified by the symbol .
In particular, it is necessary to ensure that all the surrounding
metal masses are equipotential. (standard
EN 60335.2.105
).
■
The appliance is equipped with an LED lighting system in
compliance with Norm
EN 62471:2009
; lamp rating: exempt
Group.
Do not look directly at the light using optical devices (bin-
oculars, cameras, magnifying glasses).