BATH MAINTENANCE

Cleaning the Bath

To clean your bath, simply use a mild, nonabrasive liq-
uid detergent solution.  You can protect and restore the
gloss to a dulled acrylic surface by applying  Meguiar's
#10 Mirror Glaze, a product specifically designed for
use on acrylic finishes.  If Meguiar's is not available, an
acrylic polish of equal quality or automotive paste wax
is acceptable.  Never use abrasive household clean-
ers on any Jacuzzi Whirlpool Bath product.

Repairs to the Surface

Minor scratches which do not penetrate the color finish
can be removed by lightly sanding with 600-grit wet/dry
sandpaper.  Restore the gloss using Meguiar's  Mirror
Glaze or automotive paste wax.

Major scratches and gouges which penetrate the acrylic
surface will require refinishing.  Ask your Jacuzzi Whirl-
pool Bath dealer for special instructions.

Purging the Whirlpool System

NOTE: THE WHIRLPOOL SYSTEM SHOULD BE
PURGED AT LEAST TWICE A MONTH

To remove accumulations of bath residue from the
whirlpool system, it is recommended that a whirlpool
bath be purged at least twice a month.  For best results,
however, we recommend that you purge your whirlpool
bath after each use using our exclusive two-part plum-
bing system cleaner made specifically for whirlpool
baths.  Systems Clean ™ is available through an autho-
rized Jacuzzi Whirlpool Bath Distributor or by calling us
direct at 1-800-288-4002.  Instructions for use:   Imme-
diately after bathing and exiting the whirlpool bath, leave
the bath water in the tub and add hot water, if necessary,
so the water is at least 2" above the highest jet.  Turn on
the unit without the aerator.  Pour the contents of the
Systems Clean Packet 1 (taking care not to get the
material on yourself) into the bath near the intake for the
circulation pump.  Repeat same process with Systems
Clean Packet 2. It is important to use Packet 1 before
Packet 2 to avoid a strong odor.
  Run the bath for 5 to
10 minutes.  Drain completely and rinse any residue.

If you have followed the standard purging instructions
above and still have an excess accumulation of bath
residue and desire an alternative cleaning mechanism,
we recommend SUPER SYSTEMS CLEAN PLUS manu-
factured by Stearns Packaging to rectify this condition.
This may be obtained by contacting us at l-800-288-
4002.  It is recommended that you follow the instructions
provided by the manufacturer with the product.  Re-
peated use may be necessary.  SUPER SYSTEMS
CLEAN PLUS
 does not replace the necessity to regu-
larly purge your whirlpool system with Systems Clean as
recommended.

(For additional information about water content, contact
us for a copy of the Jacuzzi Water Quality Primer.)

NOZZLE

ROLLER BEARING CASING

PUSH FROM
REAR TO
REMOVE NOZZLE

12

Bath Additives

NOTE: DO NOT USE OIL OR OIL BASED BATH
ADDITIVES.

If you want to use any kind of bath additive, use only a
small amount of low-foaming powder or crystal sub-
stance; the whirlpool action intensifies the foaming prop-
erties of soaps.

The use of certain bath oils, bubble baths and bath
additives may increase the level of accumulations of
bath residue in the whirlpool system.  If excess accumu-
lations persist, you should discontinue use of these
products.

Spinning Neck Jets

If hair or other kind of debris gets caught in the bearings
of these jets, it could cause them to stop spinning.  This
may require disassembly and cleaning.  To do this,
simply grab the nozzle and pull straight out of the jet
housing.  The roller bearing casing will be attached to the
nozzle.  These can be separated by holding the casing
and pushing the nozzle out from the rear of the casing.
After cleaning, reassemble in reverse.

Summary of Contents for S198

Page 1: ...Affinity Owner s Manual...

Page 2: ...AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISKOFHYPERTHERMIA PEOPLEUSINGMEDICATIONSAND ORHAVINGANADVERSEMEDICALHISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WI...

Page 3: ..._____________________________ 7 Water Supply________________________________________________________________________ 7 Operation _______________________________________________________________________...

Page 4: ...RICAL REQUIREMENTS BATH 115 VAC 60 Hz 30 Amp Single Phase Must be Class A GFCI Protected The unit must be hard wired permanent from this circuit to the control box ELECTRICAL REQUIREMENTS RAPIDHEAT HE...

Page 5: ...uld not be removed until final cleanup Important Read complete instructions before beginning installation Each whirlpool bath arrives ready for installation completely equipped with motor pump assembl...

Page 6: ...CD Radio ground ing wire CD Radio chassis to control box bonding bar coiled under the bath rim Run wires through wall cutout to CD Radio build out 38 9 MIN BATH PERIMETER 1x4 NOT FOR SUPPORT FINISHED...

Page 7: ...s for future use Run wires through sleeve Insert sleeve into build out When flush bend appropriate tabs to hold sleeve firmly in place Connect the speaker power connector and TV audio to the CD radio...

Page 8: ...eaker wires to back cover speakers observing polarity right speaker purple and purple w black stripe left speaker green and green w black stripe Then position back cover by sliding downward over gaske...

Page 9: ...elow For operation refer to the RapidHeat instruc tions DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter We recommend that a qualified electricia...

Page 10: ...arrant connections of water supply fittings and piping fill systems or drain overflow systems Nor is it respon sible for damage to the bath which occurs during instal lation CAUTION A nonflammable pro...

Page 11: ...e must be repeated starting from step 1 For Bath 1 Press and release the Bath button 2 Press and hold the BLOWER button The LED will flash 3 While holding the BLOWER button press the POWER button for...

Page 12: ...odes will be erased NOTE Batteries installed with incorrect polarity may leak and damage the remote control Do not mix old and new batteries or carbon types with alkaline types REAR SIDE COVER COVER R...

Page 13: ...CLOCKWISE TO REDUCE AIR FLOW TURN COUNTER CLOCKWISE TO INCREASE AIR FLOW AIR INDUCTION CONTROLS DIRECTIONALLY ADJUSTABLE FULLY ADJUSTABLE JETS CD Radio For operation of the CD radio consult the manual...

Page 14: ...yourself into the bath near the intake for the circulation pump Repeat same process with Systems Clean Packet 2 It is important to use Packet 1 before Packet 2 to avoid a strong odor Run the bath for...

Page 15: ...acuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance 13 NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSE...

Page 16: ...14...

Page 17: ...53 mm 182 mm TEMPLATE FOR CD RADIO MOUNTING SLEEVE 15...

Page 18: ......

Page 19: ...acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet...

Page 20: ...obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the...

Reviews: