background image

Note:  This is a professional grade product.  A knowledge of construction techniques, plumbing
and electrical installation according to codes are required for proper installation and user satis-
faction.  We recommend that a licensed contractor perform the installation of all Jacuzzi Whirlpool
Bath products.  Our warranty does not cover improper installation related problems.

IMPORTANT SAFETY INSTRUCTIONS

READ AND FOLLOW ALL INSTRUCTIONS

SAVE THESE INSTRUCTIONS

WARNING:  RISK OF ACCIDENTAL INJURY OR DROWNING;  CHILDREN SHOULD NOT USE HYDROMASSAGE BATHTUB
WITHOUT ADULT SUPERVISION.

WARNING :  TO AVOID INJURY, EXERCISE CAUTION WHEN ENTERING OR EXITING THE HYDROMASSAGE BATHTUB

WARNING:  RISK OF ACCIDENTAL INJURY OR DROWNING;  DO NOT USE HYDROMASSAGE BATHTUB UNLESS ALL
SUCTION GUARDS ARE INSTALLED TO PREVENT BODY AND HAIR ENTRAPMENT.

WARNING:  KEEP BODY AND HAIR A MINIMUM OF 6" AWAY FROM SUCTION FITTING AT ALLTIMES WHEN THE
WHIRLPOOL SYSTEM IS OPERATING.  HAIR LONGER THAN SHOULDER LENGTH SHOULD BE SECURED CLOSE TO THE
HEAD.

WARNING:  

NEVER DROP OR INSERT ANY OBJECT INTO ANY OPENING.

WARNING:  RISK OF ELECTRICAL SHOCK;  DO NOT PERMIT ELECTRICAL APPLIANCES (SUCH AS HAIR DRYER, LAMP,
TELEPHONE, RADIO OR TELEVISION) WITHIN 60" (1.5 M) OF THIS HYDROMASSAGE BATHTUB.

WARNING:  RISK OF ACCIDENTAL INJURY OR DROWNING;  DO NOT USE DRUGS OR ALCOHOL BEFORE OR DURING
THE USE OF HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER TO AVOID UNCONSCIOUSNESS AND POSSIBLE
DROWNING.

WARNING:  RISK OF FETAL INJURY;  PREGNANT OR POSSIBLY PREGNANT WOMEN SHOULD CONSULT A PHYSICIAN
BEFORE USING A HYDROMASSAGE BATHTUB EQUIPPED WITH A HEATER.

WARNING:  RISK OF HYPERTHERMIA AND POSSIBLE DROWNING;  DO NOT USE A HYDROMASSAGE BATHTUB
EQUIPPED WITH A HEATER IMMEDIATELY FOLLOWING STRENUOUS EXERCISE.

CAUTION;  TEST THE GROUND FAULT CIRCUIT INTERRUPTER PROTECTING THIS APPLIANCE PERIODICALLY IN
ACCORDANCE WITH MANUFACTURER'S INSTRUCTIONS.

WARNING:  RISK OF HYPERTHERMIA AND POSSIBLE DROWNING; WATER TEMPERATURE IN EXCESS OF 100

°

F (38

°

 C)

MAY BE INJURIOUS TO YOUR HEALTH.  CHECK AND ADJUST WATER TEMPERATURE BEFORE USE.

WARNING:  RISK OF HYPERTHERMIA;  PEOPLE USING MEDICATIONS AND/OR HAVING AN ADVERSE MEDICAL HISTORY
SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WITH A HEATER.

AN EQUIPMENT GROUNDING TERMINAL IS PROVIDED IN THE FIELD WIRING COMPARTMENT.  TO REDUCE THE RISK
OF ELECTRICAL SHOCK, THIS TERMINAL MUST BE CONNECTED TO THE GROUNDING MEANS PROVIDED IN THE
ELECTRICAL SUPPLY PANEL WITH A CONNECTOR EQUIVALENT IN SIZE TO THE CIRCUIT CONNECTORS SUPPLYING
THIS EQUIPMENT.

PRECAUTIONS

Do not operate the whirlpool system unless the bath is filled with water to at least 2" above the highest jet.

Do not use oil-based bath additives in your whirlpool bath.

When cleaning your bath, do not use abrasive substances which will damage the bath's surface.

To prevent discoloration of the acrylic finish, do not fill the bath with water in excess of 140

°

F (60

°

C).

The whirlpool system should be purged at least twice a month.  For your convenience, we have developed a plumbing system

cleaner (Systems Clean™) specifically for whirlpool baths.  For availability call 1-800-288-4002.

Use this unit only for its intended purpose as described in this manual.  Do not use attachments not recommended by the

manufacturer.

This unit must be connected only to a supply circuit that is protected by a ground fault circuit interrupter (GFCI).  Such a GFCI

should be provided by the installer and should be tested on a routine basis.  To test the GFCI, push the test button.  The GFCI should
interrupt power. Push the reset button.  Power should be restored.  If the GFCI fails to operate in this manner, there is a ground
current flowing, indicating a possibility of an electric shock. Do not use this unit.  Disconnect the unit and have the problem corrected
by a qualified electrician before using.

A pressure wire connector is provided on the exterior of the motor to permit connection of an No. 8 AWG (8.4 mm) solid copper

bonding conductor between this unit and all other electric equipment and exposed metal in the vicinity, as needed to comply with
local requirements.

This unit should be installed by a licensed electrician and grounded.

For built-in and drop-in units, install to permit access for servicing.

Summary of Contents for S198

Page 1: ...Affinity Owner s Manual...

Page 2: ...AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISKOFHYPERTHERMIA PEOPLEUSINGMEDICATIONSAND ORHAVINGANADVERSEMEDICALHISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WI...

Page 3: ..._____________________________ 7 Water Supply________________________________________________________________________ 7 Operation _______________________________________________________________________...

Page 4: ...RICAL REQUIREMENTS BATH 115 VAC 60 Hz 30 Amp Single Phase Must be Class A GFCI Protected The unit must be hard wired permanent from this circuit to the control box ELECTRICAL REQUIREMENTS RAPIDHEAT HE...

Page 5: ...uld not be removed until final cleanup Important Read complete instructions before beginning installation Each whirlpool bath arrives ready for installation completely equipped with motor pump assembl...

Page 6: ...CD Radio ground ing wire CD Radio chassis to control box bonding bar coiled under the bath rim Run wires through wall cutout to CD Radio build out 38 9 MIN BATH PERIMETER 1x4 NOT FOR SUPPORT FINISHED...

Page 7: ...s for future use Run wires through sleeve Insert sleeve into build out When flush bend appropriate tabs to hold sleeve firmly in place Connect the speaker power connector and TV audio to the CD radio...

Page 8: ...eaker wires to back cover speakers observing polarity right speaker purple and purple w black stripe left speaker green and green w black stripe Then position back cover by sliding downward over gaske...

Page 9: ...elow For operation refer to the RapidHeat instruc tions DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter We recommend that a qualified electricia...

Page 10: ...arrant connections of water supply fittings and piping fill systems or drain overflow systems Nor is it respon sible for damage to the bath which occurs during instal lation CAUTION A nonflammable pro...

Page 11: ...e must be repeated starting from step 1 For Bath 1 Press and release the Bath button 2 Press and hold the BLOWER button The LED will flash 3 While holding the BLOWER button press the POWER button for...

Page 12: ...odes will be erased NOTE Batteries installed with incorrect polarity may leak and damage the remote control Do not mix old and new batteries or carbon types with alkaline types REAR SIDE COVER COVER R...

Page 13: ...CLOCKWISE TO REDUCE AIR FLOW TURN COUNTER CLOCKWISE TO INCREASE AIR FLOW AIR INDUCTION CONTROLS DIRECTIONALLY ADJUSTABLE FULLY ADJUSTABLE JETS CD Radio For operation of the CD radio consult the manual...

Page 14: ...yourself into the bath near the intake for the circulation pump Repeat same process with Systems Clean Packet 2 It is important to use Packet 1 before Packet 2 to avoid a strong odor Run the bath for...

Page 15: ...acuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance 13 NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSE...

Page 16: ...14...

Page 17: ...53 mm 182 mm TEMPLATE FOR CD RADIO MOUNTING SLEEVE 15...

Page 18: ......

Page 19: ...acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet...

Page 20: ...obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the...

Reviews: