background image

TV Installation

Remove back cover by lifting straight upward and then
remove the drip shield.  Tighten cable tie and cut off
excess.  Tighten cable tie with anchor (not supplied) to
the TV power cord.  It is not necessary to attach anchor
to drip shield;  the cable tie and anchor are used to
ensure the TV power cord remains in the TV housing.
Locate blackout panel and peel protective backing off
adhesive.  Position blackout panel onto TV screen and
press adhesive to TV.  Position TV on shelf and hook up
power cord, audio and cable TV cables.  Slide TV flush
to front window.  Make sure the sensor hole on the
blackout panel aligns with the TV sensor.  If they do not
align, adjust the shelf with positioning feet till they are
aligned.  Reinstall drip shield.  Connect speaker wires to
back cover speakers observing polarity:  right speaker
and purple w/black stripe -;  left speaker green
+ and green w/black stripe -.  Then position back cover
by sliding downward over gasket seal.  Make sure
gasket seal did not detach from bath shell (extra gasket
material has been provided).  Secure with screws (an
offset screwdriver is provided).  An internal fan is pro-
vided to cool and ventilate the TV compartment.  The fan
will turn on in some instances depending on the thermo-
stat within the TV compartment.

RED

BLACK

FAN

AUDIO
CABLE

TV POWER CORD

CABLE TV

DRIP SHIELD

DRIP SHIELD WIRING

TO CABLE TV LINE

TO STEREO AUDIO
INPUT OF CD/RADIO

REAR OF TV

DC INPUT

TV CONNECTIONS

VIDEO/AUDIO FROM
EXTERNAL DVD OR VCR

DRIP SHIELD

BLACKOUT PANEL

POWER, AUDIO AND
CABLE TV/ANT. CABLES

DOUBLE SIDED TAPE
TOP AND BOTTOM
PEEL PROTECTIVE
BACKING OFF ADHESIVE.

GENTLY PUSH TV AS
FAR FOWARD TO WINDOW

REMOTE
CONTROL
SENSOR

BACK COVER

SCREWS (3)

SPEAKER WIRES

6

Summary of Contents for S198

Page 1: ...Affinity Owner s Manual...

Page 2: ...AND ADJUST WATER TEMPERATURE BEFORE USE WARNING RISKOFHYPERTHERMIA PEOPLEUSINGMEDICATIONSAND ORHAVINGANADVERSEMEDICALHISTORY SHOULD CONSULT A PHYSICIAN BEFORE USING A HYRDOMASSAGE BATHTUB EQUIPPED WI...

Page 3: ..._____________________________ 7 Water Supply________________________________________________________________________ 7 Operation _______________________________________________________________________...

Page 4: ...RICAL REQUIREMENTS BATH 115 VAC 60 Hz 30 Amp Single Phase Must be Class A GFCI Protected The unit must be hard wired permanent from this circuit to the control box ELECTRICAL REQUIREMENTS RAPIDHEAT HE...

Page 5: ...uld not be removed until final cleanup Important Read complete instructions before beginning installation Each whirlpool bath arrives ready for installation completely equipped with motor pump assembl...

Page 6: ...CD Radio ground ing wire CD Radio chassis to control box bonding bar coiled under the bath rim Run wires through wall cutout to CD Radio build out 38 9 MIN BATH PERIMETER 1x4 NOT FOR SUPPORT FINISHED...

Page 7: ...s for future use Run wires through sleeve Insert sleeve into build out When flush bend appropriate tabs to hold sleeve firmly in place Connect the speaker power connector and TV audio to the CD radio...

Page 8: ...eaker wires to back cover speakers observing polarity right speaker purple and purple w black stripe left speaker green and green w black stripe Then position back cover by sliding downward over gaske...

Page 9: ...elow For operation refer to the RapidHeat instruc tions DANGER RISK OF ELECTRIC SHOCK Connect only to a circuit protected by a Ground Fault Circuit Interrupter We recommend that a qualified electricia...

Page 10: ...arrant connections of water supply fittings and piping fill systems or drain overflow systems Nor is it respon sible for damage to the bath which occurs during instal lation CAUTION A nonflammable pro...

Page 11: ...e must be repeated starting from step 1 For Bath 1 Press and release the Bath button 2 Press and hold the BLOWER button The LED will flash 3 While holding the BLOWER button press the POWER button for...

Page 12: ...odes will be erased NOTE Batteries installed with incorrect polarity may leak and damage the remote control Do not mix old and new batteries or carbon types with alkaline types REAR SIDE COVER COVER R...

Page 13: ...CLOCKWISE TO REDUCE AIR FLOW TURN COUNTER CLOCKWISE TO INCREASE AIR FLOW AIR INDUCTION CONTROLS DIRECTIONALLY ADJUSTABLE FULLY ADJUSTABLE JETS CD Radio For operation of the CD radio consult the manual...

Page 14: ...yourself into the bath near the intake for the circulation pump Repeat same process with Systems Clean Packet 2 It is important to use Packet 1 before Packet 2 to avoid a strong odor Run the bath for...

Page 15: ...acuzzi Whirlpool Bath makes no representation or warranty regarding and will not be responsible for any code compliance 13 NOTCH GASKET COVER STRAINER SCREW SUCTION FITTING SUCTION COVER STRAINER ASSE...

Page 16: ...14...

Page 17: ...53 mm 182 mm TEMPLATE FOR CD RADIO MOUNTING SLEEVE 15...

Page 18: ......

Page 19: ...acts of God such as lightning floods earthquakes etc In addition THE COMPANY WILL NOT BE RESPONSIBLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES or losses arising from any cause e g water damage to carpet...

Page 20: ...obtain warranty replacement for factory installed components for Company supplied options and accessories manufactured and supplied by the Company call or write the above Provide a description of the...

Reviews: