33
10.4
The Se ngs Screen
The Se ngs Screen is where all programming and other swim spa behaviours are controlled.
Each icon on the Se ngs screen takes you to a different screen, where one or more se ng
may be viewed and/or edited.
The Heat Icon
takes you to a screen where you control the
Het Mode and the Temperature Range.
Dual Temperature Ranges
High vs. Low
This system incorporates two temperature range se ngs with independent set temperatures.
The specific range can be selected on the Se ngs screen and is visible on the Main Screen in
the upper le corner of the display. These ranges can be used for various reasons, with a com-
mon use being a “ready to use” se ng vs. a “vaca on” se ng. Each range maintains its own
set temperature as programmed by the user. This way, when a range is chosen, the swim spa
will heat to the set temperature associated with that range.
High Range can be set between 80
o
F and 104
o
F
Low Range can be set between 50
o
F and 99
o
F
Freeze Protec on is ac ve in either range.