Page 74
J-400
13.
System Test 2:
Reconnect the CLEAR
RAY
unit to the controller.
Turn breaker back ON. Turn on the pump to circulate the water
through the CLEAR
RAY
System. Wait for 5 minutes and assure no
water is dripping. If water is visible, STOP, fix the leak by repeating
quartz tube maintenance process from step 1 through step 12.
Make
sure there is no water visible. Turn the pump and breaker OFF
BEFORE proceeding to step 14.
14. Reconnect the UV bulb socket (6) to the power cord socket (4) make
sure you use the latex glove provided when handling the UV bulb.
WARNING:
DO NOT TOUCH THE NEW UV BULB WITH
YOUR BARE HAND.
Oil on your skin will cause hot spot on
the UV bulb and shorten the life of your UV bulb. Use the pro-
vided latex glove to handle the UV bulb.
!
15. Slide the new UV bulb (7) back inside the quartz tube.
16. Reinstall the black bulb boot (5) back over the quartz seal
compression nut (9).
17. Reinstall the enclosure cover (2) and secure with the screws.
18. Properly dispose of the old UV bulb.
WARNING:
This CLEAR
RAY
System includes a UV bulb,
which contains mercury. Dispose of the bulb in accordance
with disposal laws. See www.lamprecycle.org.
!
19. Once power is activated you can check the ballast,
Figure 14.5g, to see if the CLEAR
RAY
System is
functioning. The power on (red) light indicates that
the CLEAR
RAY
System is being provided power
and should always be on. The lamp on (green) light
indicates that UV bulb is activated.
15.0 Error/Display Messages
There are a number of unique functions designed into
your Jacuzzi spa to protect it from damage and/or to aid in
troubleshooting. When this occurs the spa will notify you by showing the
screen below, Figure 15.0a. A solid white light indicates that all
operations are normal. A solid red light indicates that immediate attention
is required to clear or fix an error code. Following is a listing of all the
possible messages along with their meanings.
Always insist on
genuine Jacuzzi replacement parts.
Note:
If you tap the display will change to Figure 15.0b. The error
icon will remain on the screen as a reminder. If the error is not taken
care of or fixed, the error display will reappear in 2 hours, Figure 15.0a.
Figure 14.5g
DANGER!
TURN POWER
OFF! DO NOT
LOOK AT LIT BULB.
SEVERE EYE
DAMAGE OR BLINDNESS
CAN OCCUR!
Power
on
Lamp
on