76
“PROCLARITY DEPTH FILTER REMINDER”
This message will appear when the filter reminder time has
expired.
I
The ProClarity Depth filter must be replaced.
“WATER REFRESH REMINDER”
This message will appear when the “Water Refresh” timer has
expired.
I
The water needs to be drained and refilled with fresh water.
“EXTENDED TEMPERATURE ACTIVATED”
The spa is set to go up to 40°C (104°F), but it can be set to reach
41°C (106°F). To access the extended temperature you need press
and hold your finger over the temperature reading for about 5
seconds. The temperature reading will start to blink to indicate
the system is ready. Tap
(
) to raise the temperature up to
41°C (106°F).
Note:
The heater icon (
) will be blinking to indicate that
the feature is active.
Troubleshooting Procedures
In the unlikely event your spa is not working the way you believe it
should, please first review all the installation and operating instruc-
tions in this manual and check the message on the panel display;
second, if you are still not satisfied it is working properly, please
follow the appropriate troubleshooting instructions.
NONE OF THE COMPONENTS OPERATE
(i.e. pump, light)
Check the control panel lights.
I
If there are letters or symbols displayed on the screen, refer to
the previous section (Error/Display Messages) to determine mean-
ing and action required.
I
If nothing appears on the display:
- Check the household circuit breaker.
- Contact dealer or authorized service center.
PUMP DOES NOT OPERATE
Activate the “JETS”
I
If no sound is detected or if you can hear a buzzing noise,
disconnect the power supply and contact an authorised
Jacuzzi® service centre.
I
If motor operates but no water flows to jets:
- Pump may not be properly primed. See instructions below.
- Contact an authorised Jacuzzi® retailer or service centre.
Pump priming instructions:
TURN SPA OFF
- Turn off the power to the spa.
- Remove the handle from the massage selector supplied by
the pump you are priming.
- Loosen the massage selector’s cap slightly (counterclock-
wise), listening for the air to seep out.
- Tighten the cap finger-tight, replace the handle and turn
the hot tub’s power back on.
Note:
This method must be used for the jet’s pumps because
these pumps are not connected to the main filter system in any
way.
CAUTION:
If freezing conditions exist and pump is not opera-
tional, take measures to protect the system from possible dam-
age from freezing. See “Winterizing”.
POOR JET ACTION.
- Make certain the jets pump is turned on.
- Check position of massage selectors.
- Open air control for selected jet system.
- Check for adequate water level.
- Check for dirty filter
WATER IS TOO HOT.
- Reduce thermostat setting.
- Switch hot tub to “Econo” mode to turn heater on only dur-
ing pre-programmed time.
- Make sure the pumps are turned off and not constantly run-
ning.
NO HEAT
- Check thermostat setting.
- Keep the cover in place while heating.
- If heater indicator is displayed, but no temperature increase
is experienced after a reasonable period of time, contact
your dealer or authorized service center.
FILTER/CIRCULATION PUMP OFF
- Verify filter/circulation pump is programmed to run 8 hours
a day.
- Make sure there are no errors preventing the pump from
turning on.
- Hot tub water is warmer than 95°F (34°C) and two degrees
warmer than the set temperature. The “Summer Logic” safety
feature has activated ((see the relevant section)).
Reminder
It’s time to replace your
ProClarity Depth filter.
Contact your authorized
dealer for a new filter.
snooze
reset
Reminder
This is a general
reminder. Please change
your water soon.
snooze
reset
ON