Loosen and remove mounting bolts 

for spacer bushings (H). 

I

I

guard screens

8

-

 

Remove spacer bushings (I) and 

guard screens from both left and 

right sides.

NOTE:

The spacer bushings (I) 

will be replaced by new 

ones included with the 

Tower Kit. Keep the remo-

ved spacer bushings (I) 

and the deflector upper 

fastening (G) in an appro-

priate place for future use 

without the Tower Kit.

6

-

 

To remove the fan guard screen, 

loosen the mounting bolt for the 

spacer bushing (F) and remove the 

deflector upper fastener (G). Next, 

tighten the mounting bolt (F) for the 

spacer bushing.

G

F

H

Summary of Contents for ARBUS 500

Page 1: ...prayers Follow instructions below for assembly ARBUS 500 ARBUS 200 TOWER KIT CTI 2012 IMP 1 Locate left and right deflectors on the rear of the machine A A 2 Loosen mounting bolts B and removebothrigh...

Page 2: ...clamp C Then disconnect thehosefromleftandrightbranches C 4 Loosen nozzle branch mounting bolts D and remove both right and left branches D D D branch hose 5 Use a screwdriver E to loosen the hose cl...

Page 3: ...hings I will be replaced by new ones included with the Tower Kit Keep the remo ved spacer bushings I and the deflector upper fastening G in an appro priate place for future use without the Tower Kit 6...

Page 4: ...twithoutspacerbushin gsandguardscreenreadyfor Tower Kit installation 1 Connect the branch hose to the Tower Kit J and tighten the clamp with a screwdriver L J L Tower Kit 2 Tower Kit with branch hose...

Page 5: ...he assembly 4 Remove nozzle holders from left and right branches 5 Install the nozzle holders with seal 1 on the Tower Kit nozzle branch 2 and 3 By placing the nozzle holder seal 1 in the hole of the...

Page 6: ...OTICE 6 6 Use the spacer bushings included in the kit and install on the Tower Kit as shown in the picture 7 Install the Tower Kit to the fan hou sing Align the spacer bushings with the holes on the f...

Page 7: ...OTICE 7 8 With Tower Kit installed insert mounting bolts into spacer bushings M and tighten M 9 With both sides of Tower Kit instal led locate the two mounting holes N and O Insert mounting bolts and...

Page 8: ...TECHNICAL NOTICE 8 10 Connect the branch hose to the quick fitting right and left sides and attach the quick fitting clamp P P 11 Machine with Tower Kit installed Arbus 200 Arbus 500...

Reviews: