AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
SECTION 6: PARTS SECTION
THERMOSTATS/FRAME ASSEMBLY/DRESS PANELS
72
THERMOSTATS
The thermostat range is from 140
°
F to 240
°
F with a maximum bulb exposure temperature of 300
°
F.
Calibration:
Wash Thermostat:
Set Point: 165
°
F (Adjustable range)
Hi-LImit Thermostat:
Fixed set point: 210
°
F (Non-adjustable)
The hi-limit thermostat is used to protect the heater element in the event of a run away regulating thermostat or a dry fire situ-
ation. It is set for 210
°
F +0
°
F or -10
°
F with a fixed set point.
This part is not adjustable.
The wash tank regulating thermostat will maintain the correct wash water temperature to meet NSF requirements. These spec-
ify that the wash be no lower than 160
°
F on hot water sanitizing machines.
To order the thermostats and corresponding decals:
Kit, Thermostat, Wash Regulating (CE Models)
06401-003-18-20
Kit, Thermostat, Wash Regulating (CS Models)
06401-003-18-21
Thermostat, High Limit Control
05930-011-49-43
1/4” Imperial Brass Fitting
05310-924-02-05
HEATER BOX COMPONENTS
Heater Box Weldment
05700-031-66-81
Heater Box Cover
05700-031-66-82
Terminal Board
05940-002-78-97
FRAME WELDMENTS
Model
Left to Right Part Number
Right to Left Part Number
AJ-54’s
05700-031-75-20
05700-031-75-20
AJ-54CGP
05700-002-65-68
05700-002-65-68
AJ-76’s
05700-031-75-25
05700-031-75-22
AJ-76CGP
05700-031-75-25
N/A
AJ-90’s
05700-031-75-26
05700-031-75-24
Bullet Feet (4 per model) - order using part number 5340-011-71-74.
FRONT DRESS PANELS
Model
Left to Right Part Number
Right to Left Part Number
AJ-54’s
05700-031-72-22
05700-031-72-22
AJ-54CGP
05700-002-63-12
05700-002-63-12
AJ-76’s
05700-031-71-85
05700-031-72-42
AJ-76CGP
05700-002-89-68
N/A
AJ-90’s
05700-031-74-06
05700-031-77-10
Summary of Contents for Enodis AJ-54 Series
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 24: ...16 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 41: ...33 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 45: ...37 SECTION 4 TROUBLESHOOTING SECTION ...
Page 49: ...41 SECTION 5 SERVICE PROCEDURES ...
Page 72: ...64 SECTION 6 PARTS SECTION ...
Page 132: ...124 SECTION 7 ELECTRICAL SCHEMATICS ...
Page 153: ...145 SECTION 8 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 160: ......