AJ-54C Series Technical Manual 7610-002-30-91
Issued: 03-22-2006 Revised: N/A
SECTION 1: SPECIFICATION INFORMATION
OPERATING CHARACTERISTICS
2
RACKS PER HOUR:
AJ-54-76-90CE/CS/CGP
270
DISHES OR GLASSES PER HOUR:
AJ-54-76-90CE/CS/CGP
6750
PREWASH TANK CAPACITY (GALLONS):
AJ-76CE/CS/CGP
16
AJ-90CE/CS/CGP
16
WASH TANK CAPACITY (GALLONS):
AJ-54-76-90CE/CS/CGP
20.4
PREWASH PUMP CAPACITY (GPM):
AJ-76CE/CS/CGP
120
AJ-90CE/CS/CGP
270
WASH PUMP CAPACITY
GALLONS PER MINUTE (ALL MODELS):
270
VENTING REQUIREMENTS (CFM)(100% CAP.):
INPUT END
200
OUTPUT END
400
TOTAL
600
CONVEYOR SPEED (FPM):
AJ-54-76-90CE/CS/CGP MACHINES
7.5
GALLONS PER RACK:
AJ-54-76-90CE/CS/CGP MACHINES
1.03
WATER TEMPERATURES:
AJ-54-76-90CE/CS/CGP MODELS:
PREWASH (RECOMMENDED) (AJ-76/AJ-90) 110-140
°
F
WASH (MINIMUM)
160
°
F
RINSE (MINIMUM)
180
°
F
FLOW PRESSURE (PSI)
20
±
5
FLOWRATE (GPM):
AJ-54-76-90CE/CS/CGP
4.7
STEAM COIL TANK HEAT (CS/CSL MODELS ONLY):
STEAM INLET PRESSURE (PSIG)
10-20
STEAM CONNECTION NPT
3/4”
CONSUMPTION @ 15 PSIG (lbs/hr):
AJ-54-76-90CS/CSL
60
MOTOR ELECTRICAL CHARACTERISTICS:
DRIVE MOTOR HP
1/4
WASH MOTOR HP
2
POWER RINSE MOTOR HP
2
PREWASH MOTOR HP:
AJ-76 MODELS
1
AJ-90 MODELS
2
NOTE: Typical Electrical Circuit is based upon (1) 125% of
the full amperage load of the machine and (2) typical
fixed-trip circuit breaker sizes as listed in the NEC 2002
Edition. Local codes may require more stringent protec-
tion than what is displayed here. Always verify with your
electrical service contractor that your circuit protection is
adequate and meets all applicable national and local
codes. These numbers are provided in this manual sim-
ply for reference and may change without notice at any
given time.
Summary of Contents for Enodis AJ-54 Series
Page 9: ...1 SECTION 1 SPECIFICATION INFORMATION ...
Page 24: ...16 SECTION 2 INSTALLATION OPERATION INSTRUCTIONS ...
Page 41: ...33 SECTION 3 PREVENTATIVE MAINTENANCE ...
Page 45: ...37 SECTION 4 TROUBLESHOOTING SECTION ...
Page 49: ...41 SECTION 5 SERVICE PROCEDURES ...
Page 72: ...64 SECTION 6 PARTS SECTION ...
Page 132: ...124 SECTION 7 ELECTRICAL SCHEMATICS ...
Page 153: ...145 SECTION 8 JACKSON MAINTENANCE REPAIR CENTERS ...
Page 160: ......