3
07610-004-04-18-R
All electrical ratings provided in this manual are for reference
only. Always refer to the machine data plate to get exact electrical
information for this machine. All electrical work performed on
machines should be done in accordance with applicable local,
state, territorial, and national codes. Work should only be
performed by qualified electricians and authorized service agents.
Note that all electrical wiring used must be rated, at a minimum,
for 212°F (100°C) and that only copper conductors must be used.
Where applicable, heating element amperage draws have been
adjusted for the assumed input voltage. The manufacturer
assumes incoming voltages will be either 208 or 230 volts.
Some heating elements used in the machines are rated for other
voltages, such as 240 volts. Always verify the amperage draw of
the machine in operation when sizing circuit protection.
If the dishmachine is equipped with the optional rinse heater, note
that the rinse heater might have its own electrical connection and
therefore require a separate service. Amperage loads for motors
and heaters are indicated on the machine data plate.
The electrical configurations are as follows:
Available Electrical Characteristics:
•
208 V, 60 Hz, Single-phase
•
230 V, 60 Hz, Single-phase
•
480 V, 60 Hz, Three-phase
Available Wash Tank Heaters:
• 14 kW
Available Rinse Tank Heaters:
• 2 kW for top tank
• 2 kW for bottom tank
AVENGER HT-E
Electrical Characteristics
ELECTRICAL REQUIREMENTS
SPECIFICATIONS
VOLTS
208
230
480
PHASE
1
1
3
FREQ
60
60
60
WASH
MOTOR
AMPS
5.0 A
5.0 A
1.3A
DRAIN
PUMP
0.6 A
0.6 A
1.0A
WASH
HEATER
AMPS
15.9 A 17.4 A
5.0A
RINSE
HEATER
AMPS
15.9 A 17.4 A
5.0A
TOTAL
LOAD
36.8 A 39.8 A 11.3A
NOTICE
i
Imbalanced wild leg
goes to L3.
Summary of Contents for AVENGER HT-E
Page 2: ......
Page 38: ...30 07610 004 04 18 R CONTROL PANEL PARTS 1 8 3 2 4 5 6 7...
Page 48: ...40 07610 004 04 18 R WASH DRAIN MOTOR ASSEMBLY PARTS 10 11 12 13 1 2 3 4 5 9 8 6 7...
Page 54: ...46 07610 004 04 18 R RINSE TANK ASSEMBLY PARTS 8 7 6 5 2 3 4 1...
Page 59: ...51 07610 004 04 18 R SCHEMATICS 480 V 60 HZ 3 PHASE...