2
07610-004-04-18-R
AVENGER HT-E
Operating Capacity:
Racks per Hour
26
Dishes per Hour
468
Glasses per Hour
936
Tank Capacity (Gallons):
Wash Tank
3
Rinse Tank
2.12
Electrical Loads (as applicable):
Wash Motor HP
0.75
Wash Heater KW
4
Rinse Heater KW
4
NOTE: Always refer to the machine data plate for specific electrical and water
requirements. The material provided on this page is for reference only and is
subject to change without notice.
Water Temperatures (Fahrenheit):
Minimum Wash Temperature
155
Minimum Rinse Temperature
180
Minimum Incoming Water Temperature
110
Other Water Requirements:
Water Flow Pressure (PSI)
10
Flow Rate Minimum (GPM)
5.16
Water Line Size (NPT)
1/2"
Drain Line Size (NPT)
1" ID
1 3/8" OD
OPERATING PARAMETERS