ProPuls 320C
Operating manual
Page 47
17.6 Advanced Welding (if activated under point 5.4)
Here, extra welding parameters can be either activated or deactivated.
With the left dial (pos. 2), the desired special function can be selected (
►
) and the value can be changed with
the right dial (pos. 5).
I2 Current:
Disabled
–secondary power I2 is not active
I2 Standard
- secondary power I2 is active with limited parameters Fx
I2 Advanced
- secondary power I2 is active with all parameters Fx
Welding crater ex:
Cr. Standard
- welding crater function is active with limited parameters Fx
Cr. Advanced
- welding crater function is active with all parameters Fx
DPuls on:
DP Standard
- double pulse function is active with limited parameters Fx
DP Advanced
- double pulse function is active with all parameters Fx
Arc L.:
Voltage
– arc length correction with voltage shown in volts
Wire speed
.– arc length correction with wire speed shown in m/min
17.7 Equipment Layout
Here, required settings for the accessories in manual or robotic welding can be configured.
Setup equipment (manual):
Here, the welding torch currently used and the ground cable can be configured.
With the left dial (pos. 2), the desired special function can be selected (
►
).
Cooling unit:
Optional
(automatic monitoring) or compulsory (must be available)
Wire feed:
Optional
(automatic monitoring) or compulsory (must be available)
U/D torch:
Torch with display – not possible at the moment
Missing
or optional (automatic monitoring) or compulsory (must be
available)
Torch:
Set torch type. The following types are possible:
AIR
– air-cooled torch, H2O – water-cooled torch
150A, 200A, 250A, 300A, 350A, 400A, 450A, 500A
PP8N / PP12N: Push-pull torch with a length of 8m and 12 m
SCC Cable:
Ground cable length
from 1 to 100 m
Robot config. (robot welding):
Only necessary and configurable in combination with a robot control.
17.8 Reset
Here, there are 3 different reset functions.
With the left dial (pos. 2), the desired reset function can be selected (
►
).
Delete all jobs?
– Hereby, only the saved jobs are deleted (ALL JOBS!!).
By pressing the special function button 2, under OK, the confirmation prompt YES or NO appears.
By pressing YES, all jobs are deleted, NO cancels the process.
Factory setting?
– Hereby only the welding parameters are reset to the factory settings.
By pressing the special function button 2, under OK,‘ the confirmation prompt YES or NO appears.
By pressing YES, all data are reset, NO cancels the process.
Reset everything?
– Hereby, both jobs and all parameters are reset.
By pressing the special function button 2, under OK,‘ the confirmation prompt YES or NO appears.
By pressing YES, everything is deleted, NO cancels the process.
17.9 STW - Software versions
Here the software versions that are currently installed on your machine are displayed.
SW Source:
Welding machine main PCB software
Curves:
Welding curve software
FDR 1:
Wire feeder 1 software
FDR 2:
Wire feeder 2 software
Torch:
Display software in the welding torch (if available)
Robot:
Robot interface software (if available)
S/N…:
Serial number of the entire machine (press ENTER / OK again)
17.10 Download / upload
In this menu, you can read and save existing data from the machine, or install new data and parameters in the
machine.
With the left dial (pos. 2), the desired special function can be selected (
►
) and the value can be changed with
the right dial (pos. 5).
Summary of Contents for ProPuls 320 Compact
Page 2: ......
Page 66: ...ProPuls 320C Operating manual Page 62 25 Ersatzteile spare parts Frontansicht front view...
Page 68: ...ProPuls 320C Operating manual Page 64 Seitenansichten side view...
Page 73: ...ProPuls 320C Operating manual Page 69 27 Schwei programme Program table...
Page 74: ...ProPuls 320C Operating manual Page 70...
Page 75: ......