Fuse

Splice

Splice

Splice

Splice

Switch

(+)

(+)

(–)

Red (+)

Red (+)

Battery

Pump

VDC Pump

Controller

(–)

(–)

(+)

Black (–)

Black (–)

Pump

Leads

Battery

Leads

Wiring

Auto-Alignment

• Disconnect the power to the pump.

• Connect pump wiring to the “PUMP” leads of the controller.

Observe proper polarity as indicated on the controller.

• Connect controller “BATT” wires to the power

supply. Observe proper polarity as indicated on

the controller.

• Turn on power to the pump circuit.

• Allow water flow to purge air from the lines. System must be

completely purged.

• When air has been purged and a smooth flow is reached, close

each valve, one valve at a time. Gradually close the last valve.

• The control will auto-align itself to the pump in a few seconds.

The system is then ready to use.

City Water

Inlet

(optional)

Water

Tank

Check Valve

used with

Water Heater

Shower

Fixture

Sink

Faucet

Existing

Water Pump

Low-Point

Drain

Inlet

Strainer

VSD Smooth-Flow™ 

Controller

Water

Heater

(optional)

Plumbing

• Turn off power to the pump.

• Shut off water supply to pump.

• Open faucets and low-point drains to relieve pressure in lines.

• Disconnect existing hose connection from pump outlet (see Figure 1).

• Connect pump discharge hose line to either line port in the controller.

Make sure the snap-fit gate fittings on the controller
snap securely into place when attaching hose
lines (see Figure 2 as example).

• Connect water system hose line 

to remaining line port of pump
controller (see Figure 2 
as example).

Pump

Outlet

Existing

Hose Connection

Pump

Outlet

Existing

Hose Connection

Figure 1

Figure 2

Summary of Contents for 31777-0000

Page 1: ...t HOW IT WORKS The controller automatically measures the pressure at which the pump s pressure switch opens It uses this measurement to determine an optimal running pressure for the given pump and stores the value in its memory for consistency between power cycles Compatible Pump Requirements Diaphragm pumps with 3 4 or 5 pumping chambers 12 or 24 VDC 12 amp maximum at 12 Volts 6 amp maximum at 24...

Page 2: ...ate Fitting to Facilitate Installation Kit Inventory Tools Required Location Pre install Remove Accumulator Tank if installed System may not operate properly if there is an accumulator tank installed anywhere in the system Mount the VSD Module as close as possible to the pump discharge Kit is set up to mount directly to pump discharge PARTS KEY 1 Water System Hose 2 Pump Elbow Hose 3 Quick Connect...

Page 3: ... itself to the pump in a few seconds The system is then ready to use City Water Inlet optional Water Tank Check Valve used with Water Heater Shower Fixture Sink Faucet Existing Water Pump Low Point Drain Inlet Strainer VSD Smooth Flow Controller Water Heater optional Plumbing Turn off power to the pump Shut off water supply to pump Open faucets and low point drains to relieve pressure in lines Dis...

Page 4: ...pump control and power supply wires and hoses should be placed so as not to interfere with any components for operation of the vessel www jabsco com 30649 1000 SNAP IN PORT x 1 2 MALE QEST STRAIGHT 30654 1000 SNAP IN PORT x 1 2 HOSE BARB STRAIGHT 30653 1000 SNAP IN PORT x 3 4 HOSE BARB STRAIGHT 30650 1000 SNAP IN PORT x GARDEN HOSE STRAIGHT 30655 1000 SNAP IN PORT x 1 2 MALE QEST 90 ELBOW 30651 10...

Reviews: