Copyright 2006, ITT Industries
Printed in China
All Rights Reserved
Form: 43000-1822
Rev A 04/2006
UNITED KINGDOM
Jabsco
Bingley Road, Hoddesdon
Hertfordshire EN11 OBU
Tel: +44 (0) 1992 450145
Fax: +44 (0) 1992 467132
CANADA
Fluid Products Canada
55 Royal Road
Guelph, Ontario N1H 1T1
Tel: (519) 821-1900
Fax: (519) 821-2569
JAPAN
NHK Jabsco Company Ltd.
3-21-10, Shin-Yokohama
Kohoku-Ku, Yokohama, 222-0033
Tel: +81-045-475-8906
Fax: +81-045-477-1162
U.S.A.
Jabsco
20 Icon
Foothill Ranch, CA 92610
Tel: (949) 859-4945
Fax: (949) 859-1153
GERMANY
Jabsco GmbH
Oststrasse 28
22844 Norderstedt
Tel: +49-40-53 53 73-0
Fax:+49-40-53 53 73-11
ITALY
Jabsco Marine Italia
Via Tommaseo, 6
20059 Vimercate, Milano
Tel: +39 039 685 2323
Fax: +39 039 666 307
ERROR CONDITION
This unit has an error code system built in. The small light
located on the front right side of the unit will indicate:
1 Blink – Pressure switch value too low (under 20 PSI)
2 Blinks – Pressure switch value too high (over 70 PSI)
3 Blinks – Maximum run time exceeded (20 minutes)
To correct any of these modes, cycle power off for at least 10
seconds, then turn back on. The control will not work on pumps
where the switch value is at or below 20 psi or above 70 psi.
PRODUCT WARRANTY
One Year Limited Warranty is available on request.
Opening the unit voids the warranty.
Note:
The wiring diagrams are offered for reference. Position
of the pump, control and power supply wires and hoses
should be placed so as not to interfere with any components
for operation of the vessel.
www.jabsco.com
30649-1000
SNAP-IN PORT x
1/2" MALE QEST.
STRAIGHT
30654-1000
SNAP-IN PORT x
1/2" HOSE BARB
STRAIGHT
30653-1000
SNAP-IN PORT x
3/4" HOSE BARB
STRAIGHT
30650-1000
SNAP-IN PORT x
GARDEN HOSE
STRAIGHT
30655-1000
SNAP-IN PORT x
1/2" MALE QEST.
90
°
ELBOW
30651-1000
SNAP-IN PORT x
1/2" HOSE BARB
90
°
ELBOW
30642-1000
SNAP-IN PORT x
3/4" HOSE BARB
90
°
ELBOW
CONTROL PORT FITTINGS AVAILABLE
Snap-In Port System
TROUBLESHOOTING CHART
Symptom
Possible Cause(s)
Corrective Action
Pump Does Not Run
Pump may be overheated
Allow pump to cool
Fuse or breaker may be open.
Check fuse or breaker
An error condition may exist
See ”Error Condition” below
Pump Runs Intermittently When Not In Use A leak in the plumbing or pressure
Check for leaks in the plumbing. Briefly
may be bleeding off through the pump
open a faucet all the way and then
sharply close it. This may clear out
debris from the pump and allow it to
seal correctly inside.
Switch Cycling
System needs re-alignment
While the pump is cycling, turn power off
for at least 10 seconds, then turn the power
back on. The controller will gradually
re-align to a reduced operating pressure.
System Runs at Very Low Pressure
The control unit has not completed pressure
Ensure that the system is fully charged
auto-alignment.
with water (purge air), then ensure all
valves are closed.
Pump Motor Hums
Pump mounting surface
None. Some hum occurs with normal
operation and is expected.