background image

 

Dear Oasis user 

The development and production of your security system have been done by 
the 

manufacturer

  with maximum care so that your oasis  of safety –  your 

room, house or company premises – can be protected as well as possible. 
The second party having an impact on the quality of a security system is the 

installer

. The installer company should know the system well, therefore do not 

hesitate to contact them if you have any questions about system operation or 
when you need an in-depth explanation of how the system works. 
However, the most important participant of a properly working security system 
is you, the daily 

user

. Please, follow these guidelines as well as the installer’s 

instructions when you take over the system. During the system’s everyday use, 
you can read information from the keypad display. This way you can be 
informed that a balcony door is open or that maintenance of a particular device 
is needed. 
 

 

What is a security system? 

Any electronic security system (ESS) has a control panel as its essential part. 
The control panel comprises all the system’s important functions. Among the 
control panel’s constituent optional parts, there is a communicator for 
transmitting messages to  an alarm receiving centre, and a back-up battery, 
which ensures that the system works properly (for a given period) after a power 
supply outage. 
The control panel should be installed in a hidden place. In the case of an 
intrusion, a hidden-working control panel transmits messages even if all other 
parts of the ESS have been destroyed. 
The connection between you and the control panel is established via a keypad. 
This way you can operate the system or, conversely, the system informs you via 
the keypad display or LED signalling. 
House premises are protected by detectors. These react to various events: 
movement (PIR), door or window opening (magnetic detector), glass pane 
breaks (glass break detector). In addition, smoke detection or combustible gas 
leak detection can be included in a system’s functionality. This way an ESS can 
detect threats to property or health. 
When a security system detects movement in a protected area, information is 
sent, depending on the system configuration, to your mobile phone or to an 
alarm receiving (central monitoring) company, which performs on-site physical 
intervention. Outdoor sirens let the neighbourhood know that something is 
going on, whereas the main purpose of indoor sirens is to discourage the 
intruder. 
 

 

Oasis user manual 

MKE22102

  

Summary of Contents for Oasis

Page 1: ......

Page 2: ...nn NC MC master code NC new code 7 for operation while under duress should be entered before the access code to secretly signal distress 8 PGX control ON OFF 81 80 or enter 8 to trigger if a pulsed s...

Page 3: ...on reserves the right to refuse warranty service if this information has been removed or changed 2 This warranty does not cover any failure of the Product due to misuse including but not limited to us...

Page 4: ......

Page 5: ...ote control by phone Internet 9 User configuration access codes cards 9 10 Programming the master code card 10 11 Programming user codes cards 10 12 Key fob setting 12 User configuration Maintenance m...

Page 6: ...tional parts there is a communicator for transmitting messages to an alarm receiving centre and a back up battery which ensures that the system works properly for a given period after a power supply o...

Page 7: ...lity can be configured during installation The system allows for up to 50 different access codes cards to be assigned to different users This way it is possible to distinguish at the alarm receiving c...

Page 8: ...g arming 2 If operation without an access code is enabled 4 you only have to press the A button to set section A the B button to set both sections A and B or the ABC button to set the entire system Wh...

Page 9: ...tion at the moment of setting to the information on the keypad If the 10 parameter is enabled then by displaying Triggered det on the keypad the system gives you notice that a detector is triggered us...

Page 10: ...delay then the exit delay is extended to the moment when the final door is closed So you can set and leave the house comfortably without any haste If the final door detector is not triggered then the...

Page 11: ...ith partial setting arming 2 Enter a code present a card Use a key fob By pressing the or button you will unset the whole system A split system 3 Enter a code present a card or use a key fob to unset...

Page 12: ...m to inconspicuously call for help After triggering a panic alarm the system will send voice messages SMS messages and pass data to an alarm receiving centre central monitoring station depending on in...

Page 13: ...description is intended for a system administrator who knows the control panel master code or possesses a master card which is authorized to modify the system configuration All the settings can be per...

Page 14: ...3 6723 If you wish to use an access card instead of a code you can enter 5 xxxx and then present the card This makes the card authorized for system configuration If you forget the master code or if yo...

Page 15: ...r has only a code or a card then verification does not concern him If the administrator records the codes on the table in the appendix of this manual it is necessary to keep it hidden in a safe place...

Page 16: ...code card The mode will be indicated on the keypad display Maintenance mode enables the following internal clock configuration automatic setting unsetting schedule programming telephone numbers for al...

Page 17: ...in damaging the device and loss of warranty Recommendations the system should be annually inspected by a professional installer who should check the backup battery voltage and perform functionality te...

Page 18: ...usly c Multiple pressing and holding of the keys 2 or 3 will toggle the bypass on off on d Using key 4 will cancel all device bypasses in the system 3 All the desired bypasses can be reprogrammed by r...

Page 19: ...schedule This can be used to program an automatic sequence of daily setting unsetting events Up to 10 daily events can be programmed The events will occur every day of the week To program an automatic...

Page 20: ...ormed everyday at the programmed time with all its consequences It means that the system will be set even when people are still on the premises To cancel a scheduled event enter 64 n 0 As a factory de...

Page 21: ...ling in the table Use the ABC column for marking the sections accessible in a split system Use the Code column to indicate that a position is occupied by a code Use the Card column to indicate that a...

Page 22: ...Device Y 15 Unsetting disarming by service code enabled 20 sec Exit delay time 21 sec Entrance delay time for a main door access 22 sec Entrance delay time for a final door access A Automatic summer t...

Page 23: ...hould be filled in by a service technician according to the system configuration composition Use the ABC column to indicate which section a device falls into Use the Type column for device type specif...

Reviews: