operatIng parameterS
niCd/niMh
Voltage level:
1.2V/cell
Allowable fast charge current:
1-2C (depending on the performance of the cell)
Discharge voltage cut off level:
NiCd:
0.85V/cell
NiMH: 1.0V/cell
LiIo
Voltage level:
3.6V/cell
Max charge voltage:
4.1V
Allowable fast charge current:
1C or less
Min. discharge voltage cut off level:
2.5V/cell or higher
LiPo
Voltage level:
3.7V/cell
Max charge voltage:
4.2V
Allowable fast charge current:
1C or less
Discharge voltage cut off level:
3.0V/cell or higher
Life
Voltage level:
3.3V/cell
Max charge voltage:
3.6V
Allowable fast charge current:
4C or less
Discharge voltage cut off level:
2.0V/cell or higher
gel Cell (Pb, Lead acid)
Voltage level:
2V/cell
Max charge voltage:
2.46V
Allowable fast charge current:
0.4C or less
Discharge voltage cut off level:
1.75V/cell or higher
nOtE: this charger has a maximum output of 50 watts. you can determine the maximum
available current (a) by dividing 50 (W) by the battery pack voltage (V). W/V = a.
the maximum safe charge current that can be set is determined by the type of cells and
the manufacturers recommendation. this is often 1C (1 x capacity of cells) for LiPo and