![J. Perkins LIPRO DUAL 6 Instruction Manual Download Page 14](http://html1.mh-extra.com/html/j-perkins/lipro-dual-6/lipro-dual-6_instruction-manual_3089718014.webp)
12
www.jperkinsdistribution.co.uk
charge & dIScharge programS
Please ensure you choose the correct process for the type of battery you will be charging
or discharging as each type of battery uses a different charge and discharge techniques.
These techniques are built into the different programs set up on the LiPro Dual 6.
LIthIUM ChargE PrOgraM
The following program is only suitable for charging Lithium batteries with a nominal
voltage of 3.3V, 3.6V and 3.7V per cell. Do not try to charge any other type of battery
using this program.
The charge current varies according to the battery capacity and performance. The final voltage of
charge process is also very important; it should be 4.2V/cell for LiPo, 4.1V/cell for LiIo and 3.6V/cell for
LiFe. If the final voltage exceeds these values by more than 1% during charge at any time the battery
will explode. The charge current, nominal voltage and cell count set on the charge program must
always be correct for the battery to be charged.
Lithium program menu:
Selecting the correct charge program:
Before using any of the Lithium charge programs you must confirm you have the correct type of
lithium battery selected for the one you are about to charge.
To do this enter the “USER SET PROGRAM” option on the main menu. The first option is “V.Type”.
Choose between LiPo (3.7V), LiIo (3.6V) and LiFe (3.3V) by pressing “Start/Enter” button and then
using the “INC” and “DEC” buttons to scroll through these choices. Once you have the correct one
selected confirm it by pressing “Start/Enter”. (See page 8 for more information on the USER SET
PROGRAM options)
INC
DEC
INC
DEC
INC
DEC
INC
DEC
INC
DEC
PROGRAM SELECT
LiXX BATT
LiXX CHARGE
-.-A -.-V(1S)
LiXX BALANCE
-.-A -.-V(1S)
LiXX FAST CHG
-.-A -.-V(1S)
LiXX DISCHARGE
-.-A -.-V(1S)
LiXX STORAGE
-.-A -.-V(1S)
Start
Enter
Batt type
Stop