![J. Perkins LIPRO DUAL 6 Instruction Manual Download Page 19](http://html1.mh-extra.com/html/j-perkins/lipro-dual-6/lipro-dual-6_instruction-manual_3089718019.webp)
17
www.jperkinsdistribution.co.uk
LIthIUM DISChargIng PrOgraM
Use this program to discharge LiPo, LiIo or LiFe batteries.
WarnIng: Do not store lithium batteries in a discharged state.
1. Select this charge process by choosing
Lixx DISChargE
from the Lithium program menu by
pressing the “Start/Enter” button. The display should look similar to this:
The value on the left of the second line denotes the discharge current and the value on the right of
the second line denotes the voltage and cell count of the battery pack to be charged.
nOtE: at this stage you need to ensure you have the correct type of battery selected for
the type you are about to discharge, if you have the wrong type selected you need to exit
the charge program immediately and change the setting in the “USEr SEt PrOgraM”
menu.
WarnIng: thE CUrrEnt VaLUE On thE LEft Of thE SECOnD LInE MUSt nOt ExCEED 1C. thE
fInaL VOLtagE On thE rIght ShOULD nOt BE UnDEr thE VOLtagE LEVEL rECOMMEnDED
By thE BattEry ManUfaCtUrEr tO aVOID OVEr DISChargIng. If yOU arE UnSUrE SEEK
aDVICE frOM yOUr LOCaL MODEL ShOP.
2. If you need to alter the settings for the discharge press the “Start/Enter” button to make it blink
then change the value with “DEC” or “INC” button. The value will be stored by pressing “Start/
Enter” button.
3. Once the settings are correct press and hold the “Start/Enter” button to begin the charge process.
The display will now show similar to the following:
4. The charger will emit a sound to inform you when the process is complete. To stop the discharge
process early press the “Batt type/Stop” button.
LiPo DISCHARGE
2.0A 9.0V(3S)
LI3s 2.0A 12.59V
DSC 0.22:43 00682