![J. Perkins LIPRO DUAL 6 Instruction Manual Download Page 16](http://html1.mh-extra.com/html/j-perkins/lipro-dual-6/lipro-dual-6_instruction-manual_3089718016.webp)
14
www.jperkinsdistribution.co.uk
LIthIUM BaLanCE ChargE PrOgraM
The following program is only suitable for charging and balancing Lithium batteries
with a nominal voltage of 3.7V, 3.6V or 3.3V/cell. Do not try to charge any other type of
battery using this program.
this program is for balancing the voltage of LiPo, LiIo or Life battery cells while charging.
to charge a LiPo, LiIo or Life battery using this program the battery needs to have a
suitable balance lead.
The BALANCE CHARGE program is different to that of the CHARGE program. In this charge process
the voltage of each individual cell is monitored and the charging current fed into each cell is
controlled to balance the voltages.
how to charge:
Follow steps 1-6 of the Lithium Charge program.
VIEWIng thE VOLtagE Of InDIVIDUaL CELLS
This charge process allows you to monitor the voltage of individual cells whilst charging.
To use this function press the “INC” button during the charge process.
The display will look similar to this:
Press “INC” again to view the remaining 5-8 cells.
ErrOr MESSagE DUrIng BaLanCIng
If the voltage of one or more cells varies abnormally during the balance charge process the LiPro
Dual 6 will immediately terminate the process and the following error will display:
To view the status of individual cells during this error message press the “INC” button.
NOTE: If there is a connection break in the circuit the voltage value may show zero.
C1:4.18 C2:4.18V
C3:4.18 C4:4.18v
Cell 2 Voltage
Cell 1 Voltage
Cell 3 Voltage
BATTERY VOL ERR
CELL LOW VOL
Cell 4 Voltage