02 J4M SERIES
HANDBOOK_
J4M SERIES
05
J4M Electric actuators operate with the use of live electricity. It is recommended that only qualified
electrical engineers be allowed to connect or adjust these actuators.
READ THESE INSTRUCTIONS BEFORE CONNECTING THE ACTUATOR. DAMAGE CAUSED BY
NON COMPLIANCE OF THESE INSTRUCTIONS IS NOT COVERED BY OUR WARRANTY.
Warning:
Ensure that the square rubber seal is in place when fixing each
DIN plug to the actuator. Failure to do so could allow water ingress and
damage caused by this installation error will invalidate any warranty. The
DIN plugs are fixed to their respective bases on the actuator housing with
a screw. Do not over tight the screw (8) when assembling (Max. 0.5Nm ).
1.
Gasket
2.
Terminal strip
3.
Cable fixing screws
4.
Housing
5.
Washer
J4M 2 to 40
6.
Grommet
7.
Gland - nut
8.
Fixing screw
9.
Washer
10.
Gasket
All our actuators model S2 to S40 are ready to work from 24-240 VDC/VAC.
All our actuators model B2 to B40 are ready to work at 12 VDC/VAC ONLY.
VOLTAGE TO BE CONNECTED
Warning:
Before connecting ensure that the voltage to be applied to the actuator is within the range
shown on the identification label. The supplied electrical connectors, used to connect to the actuator
are DIN plugs. Ensure the diameter of cable to be used conforms to the maximum and minimum
requirements of the DIN plugs to maintain water tightness (Fig.1).
ELECTRICAL CONNECTORS
Summary of Contents for S2
Page 1: ...www jjbcn com HANDBOOK J J BCN INTERNACIONAL S A...
Page 12: ...J4M 2 SIZES HANDBOOK_DATASHEET J4M 2 _12 INDEX...
Page 14: ...J4M 6 SIZES HANDBOOK_DATASHEET J4M 6 _14 INDEX...
Page 16: ...J4M 10 SIZES HANDBOOK_DATASHEET J4M 10 _16 INDEX...
Page 18: ...J4M 25 SIZES INDEX HANDBOOK_DATASHEET J4M 25_18...
Page 20: ...J4M 40 SIZES INDEX HANDBOOK_DATASHEET J4M 40_20...