OCEANO HD-55
PULL & LIFT
AR861 FSR
User Guide
Page 1: ...OCEANO HD 55 PULL LIFT AR861 FSR User Guide...
Page 2: ......
Page 3: ...warranties either express or implied included but not limited to implied warranties of merchantability and fitness for a particular purpose with respect to this product and documentation iXBlue reser...
Page 4: ...functions or damages caused by improper use or inadequate maintenance of the product Under no circumstances shall iXBlue be due to provide repair or replacement under this warranty in order a to repai...
Page 5: ...directories programs functions filenames and extensions italic Italic text is the result of an action in the procedures Icons The Note icon indicates that the following information is of interest to...
Page 6: ...and Acronyms AUV Automated Unmanned Vehicle CAF Common Acknowledgment Frequency FSK Frequency Shift Key OCV Open Circuit Voltage RL Release Load SWL Safe Working Load TL Test Load TVR Transmit Voltage...
Page 7: ...HE HD 55 6 III 1 Safety Recommendations 6 III 1 1 General Safety Recommendations 6 III 1 2 Pre Operation Safety Recommendations 6 III 2 Checking or Operating the AR861S Acoustic Actuator 7 III 2 1 Usi...
Page 8: ......
Page 9: ...ntal pulling applications Figure 1 HD 55 with acoustic actuator The HD 55 is supplied with a 60 t SWL safe working load oval master link A515C65 compatible with the FSR release hook The whole assembly...
Page 10: ...ediate part situated between the triggering system and hook designed for load releasing purposes and load reduction Hook 9103084 designed to hook up and release the master link tied to the external lo...
Page 11: ...t of acoustic actuator 25 kg Weight of ring 33 kg Weight of complete assembly without ring 300 kg Safe Working Load SWL 55 t Release Load RL 40 t Test Load TL 90 t Minimum Release Load 1 t Depth ratin...
Page 12: ...st had been completed and checked for by iXBlue shortly before shipment II 2 Handling and Transport For transport it is strongly recommended that the HD 55 unit is in armed position and fitted with th...
Page 13: ...tery pack Charging the battery pack is recommended on regular basis every 3 months II 3 3 1 After One Week Storage Step Action 1 Visual inspection of the complete unit 2 Verify that the mechanical sys...
Page 14: ...ULATIONS AND WITH THE DESIGN GUIDELINES NI184 FROM BUREAU VERITAS IN ORDER TO MAINTAIN THE ORIGINAL PERFORMANCES AND TO ENSURE SAFETY IN OPERATION THE EQUIPMENT MUST BE USED ACCORDINGLY TO THE CONDITI...
Page 15: ...ng upwards III 2 2 USING TT301B REMOTE CONTROL UNIT Step Action 1 First initialize the surface remote control equipment and the receiver mode as indicated in the TT301B User Guide Place the dunking tr...
Page 16: ...LL DOES NOT WORK CHECK THAT THE TRANSDUCER OF THE REMOTE CONTROL DOES NOT BUMP AGAINST THE VESSEL HULL THE VESSEL IS NOT MOVING TOO QUICKLY CAUSING TURBULENCE NO FREQUENCY OR CODE ERROR HAS BEEN MADE...
Page 17: ...that the fork locking pin 9101550 of the acoustic actuator is in release position parallel to the arms of the fork lever 9102893 and can be inserted inside these arms 2 Otherwise through the acoustic...
Page 18: ...in contact with the hook 7 Manually set the fork shaped lever 9102893 to bring the long section of the lever 9102981 in contact between the arms of the said fork shaped lever and push the arms in a di...
Page 19: ...201 2903202 2903203 FOR THE NEXT RELEASE OPERATION THIS OPERATION IS VITAL IF OMITTED THE FORK SHAPED LEVER 9102893 AND LEVER 9102981 MAY BE DAMAGED NOW THE OCEANO HD 55 HEAVY DUTY ACOUSTIC RELEASE IS...
Page 20: ...ocking pin 9101550 rotates by 90 after a 3 seconds delay and make free the release mechanism after about 3 or 4 additional seconds When motor stops turning a second acknowledgement pulse is transmitte...
Page 21: ...he arrow indication clockwise situated on the frame will break the plastic ROV handle locking pin 9102729 torque 2 5 mdaN after a first quarter turn 90 clockwise and drives the mechanical releasing ax...
Page 22: ...L T6 for wet environment grade NLGI2 4 Check or fit the flat faces of the ROV axis 9103085 in line with unit main axis 5 Rock the two web flanges 910 2709 into the housings of the supporting plate 910...
Page 23: ...YSTEM OF THE FSR TYPE SHALL BE PERFORMED BY SKILLED PERSONNEL DISMANTLING AND RE ASSEMBLY OF THE VARIOUS PARTS MUST BE PERFORMED IN A CLEAN AREA LUBRICATE PARTS WHICH HAVE BEEN CLEANED WITH A GREASE G...
Page 24: ...lush the whole unit with sea water 2 When all foreign particles have been removed flush the assembly with fresh water 3 Visually inspect the acoustic actuator for proper condition and in particular th...
Page 25: ...10 handle None None Part 1 Removing the sheave Refer to drawing 2909202 for parts identification Step Action 1 Remove the split pin GFV5 65 S 2 Remove the nut 9102984 2 of the top axis 9102984 1 and t...
Page 26: ...10 minutes Part 2 Removing the hook Step Action 1 Remove the split pin GFV5 65 S 2 Remove the nut 9102984 2 of the bottom hook axis 9102984 1 and the washer 9102986 3 While holding the releasing hook...
Page 27: ...he lever and washer 910298 5 End of procedure Part 4 Removing the back up ROV handle Step Action 1 Remove the plastic handle safety pin ROV 9102729 after having removed the split pin size 2 5 x 30 2 R...
Page 28: ...and fork shaped lever assembly 2 Using a handle pivot the axis 9103085 in order to clear the supports 9102709 like a mechanical releasing operation 3 Recover and disassemble the two flanges 9102709 th...
Page 29: ...ubject Re assembling the HD 55 Maintenance level 2 Duration 10 minutes Mechanical tools None None Perform the above stated operations in the reverse order not omitting to clean and grease the parts pr...
Page 30: ...he frame 3 End of procedure Part 2 Opening the Actuator Step Action 1 Put the acoustic actuator horizontally 2 Using one Allen hexagonal key size 10 remove the screw on the opposite side of the acoust...
Page 31: ...osing cover seals and check the condition of the screw joints and change them if there is the slightest trace or scratch JTR50 DF801 2 Grease the seals with silicon grease e g RHONE POULENC or MOLIKOT...
Page 32: ...n to change parameters Then press 1 to access the Immediate Transmit menu 4 According to individual data sheet of the device select type of device AR8 or RT8 then the type of transmission Generally se...
Page 33: ...Control Transmitter The ranging information is then displayed 4 No other operation then transmitting CAF pulses is expected from the Acoustic Actuator 5 End of procedure Part 5 Release operation Step...
Page 34: ...rocedure described in item 6 replacing PINGER ON settings by PINGER OFF and Other CMD type of command Acoustic device should stop the free running transmitting mode Part 7 DIAGNOSTIC mode Step Action...
Page 35: ...PPORT HELPLINE FOR NON EMERGENCY SUPPORT support ixblue com FOR GENUINE EMERGENCIES ONLY North America NORAM 1 888 600 7573 Extension 2 Europe Middle East Africa Latin America EMEA LATAM 33 1 30 08 98...
Page 36: ...Middle East Africa Latin America EMEA LATAM 33 1 30 08 88 88 iXBlue SAS Marly France 52 avenue de l Europe Marly le Roi 78160 France Offices Dubai Germany Netherlands Norway UK Italy Asia Pacific APA...
Page 37: ...MP9101554A Backstop abutment locking 3 MT9101555 Locking spring 2 MP9101559 Counter plate 3 MP9102708A Hook support 1 MP9102709B Flange 2 Super Duplex Stainless Steel MP9102720A Flange axle washer 2 M...
Page 38: ...MVCHC10 35 S CHC screw M10x35 inox 2 MVCHC10 40 S CHC screw M10x40 inox 4 MVCHC10 50 S CHC screw M10x50 inox 2 MVF90M8 20 S Frased head CHC screw inox 8 MVG3 25 S Pin 3x25 inox 3 MVG8 39660 Spring pin...
Page 39: ...OCEANO HD 55 Pull Lift User Guide MU HD55P L AN 001 Ed G October 2013 31...
Page 40: ...OCEANO HD 55 Pull Lift User Guide MU HD55P L AN 001 Ed G October 2013 32...