REL 1.2
Page 50 of 56
iWave Systems Technologies Pvt. Ltd.
i.MX6 SODIMM SOM Hardware User Guide
3.2
Environmental Characteristics
3.2.1
Environmental Specification
The below table provides the Environment specification of i.MX6 SODIMM SOM.
Table 10: Environmental Specification
Parameters
Min
Max
Operating temperature range (Industrial)
¹
-40°C
85°C
Operating temperature range (Commercial)
¹
0°C
70°C
Humidity - Operating
10%RH
90%RH
Humidity - Storage
5%RH
95%RH
¹ iWave guarantees the component selection for the given operating temperature. The operating temperature at the
system level will be affected by the various system components like carrier board and its components, system
enclosure, air circulation in the system, system power supply etc. Based on the system design, specific heat
dissipating approach might be required from system to system. It is recommended to do the necessary system level
thermal simulation and find necessary thermal solution in the system before using this board in the end application.
3.2.2
RoHS Compliance
iWave’s
i.MX6 SODIMM SOM is designed by using RoHS compliant components and manufactured on lead free
production process.
3.2.3
Electrostatic Discharge
iWave’s
i.MX6 SODIMM SOM is sensitive to electro static discharge and so high voltages caused by static electricity
could damage some of the devices on board. It is packed with necessary protection while shipping. Do not open or
use the SOM except at an electrostatic free workstation.