CAUTION
• Install the pump according to a drawing and specification.
• Keep a wide working space for convenience in maintenance.
2. Installation location
Select an installation location under the following conditions for the prevention of damage and
deformation.
1. Ambient temperature between 0 - 40 ºC
2. A location free from water influx at any time of an accident or casualty
3. A location provided with plumbing equipment
4. Humidity between 35 - 85%RH (Keep good ventilation.)
5. A location free from wind & rain (Except outdoor use)
6. A clean atmosphere
7. Non freezing in winter time
Installation
● Do not drop the pump
Do not drop, hit or drag the pump during carrying in or installation.
● Ventilation
Poisoning may result when handling an odorous/harmful liquid. Keep good
ventilation in your operating site.
● Do not hit plastic pump parts
The front case, rear case and base are plastics. Always keep the plastic parts
free from an impact.
● Keep the pump free from pipe weight
Plastic pump parts may deform or break. Always support pipework so as not
to weigh the pump.
Caution
Caution
Caution
1. Before installation
Precautions for electrical wiring and pipework