background image

DESCRIPTION OF LED / OVERVIEW OF FUNCTIONS 

 

1

 

 

 

6 V mode (7.2 V/1 A) 

 
2

 

 

12 V mode (14.4 V/1 A) 

 
3

 

 

Short-circuit of the connection cable (LED flashes) or battery is defective (LED is on)

 

 

4   

 

Charge status display (flashes during charging process and is on when the rechargeable 

battery is full)

 

 

 

 
CHARGING A LEAD-ACID BATTERY 

 
•  First ensure that it is a lead-acid battery with a voltage of 6 V or 12 V. Rechargeable batteries with other voltages cannot be charged! 
•  Disconnect all consumers from the rechargeable battery. 
•  If the rechargeable battery is built into a vehicle, switch off the ignition and all consumers. 
 
 

Please strictly observe any and all information and safety instructions of the vehicle on how the rechargeable vehicle battery needs to be 
charged. Modern vehicles are equipped with sensitive electronic components and control units which will be damaged when handled 
improperly!

 

 
•  First, connect the charger to a mains socket (220 – 240 VAC/50/60 Hz).  
•  Now, connect the charger to the rechargeable battery observing correct polarity. Reverse polarity on the connected rechargeable battery is indicated by LED 3. 
•  Then, you may select one of the two modes by activating the MODE button. The next chapter contains the description of the individual operating modes. 

¼

  Only in the first 10 seconds after connecting the rechargeable battery, it is possible to select the desired charge mode. If you, for example, selected the 

 

wrong mode, you must disconnect the rechargeable battery once again from the charger and reconnect it.

 

•  After charging, disconnect the charger from the mains voltage. 
•  Then remove the terminal from the minus pole of the rechargeable battery and then from the plus pole. 

 

 
DESCRIPTION OF OPERATING MODES 

 

 

6V mode (1) 

The 6 V-mode is suitable for charging rechargeable 6 V batteries with a capacity from 1.2 Ah (please observe the technical data of the battery manufacturer 
concerning the maximum charging current). 
Press the MODE button again and again until LED 1 flashes. After approx. 

10 seconds

 the LED is constantly on and the charging procedure starts.

 

The charging current is 1 A +/- 10%. At approx. 7.1 V the charging current will be reduced to 0.6 A. The charging end voltage is 7.2 V +/- 0.2 V. 
LED 4 indicates the charge status. When the LED is constantly on, the rechargeable battery is full. 

 

 
12V mode (2) 

The 12V mode is suitable for charging rechargeable 12 V batteries with a capacity from 1.2 Ah (please observe the technical data of the battery manufacturer 
concerning the maximum charging current). 
Press the MODE button again and again until LED 2 flashes. After approx. 10 seconds the LED is constantly on and the charging procedure starts.

 

The charging current is 1 A +/- 10%. At approx. 14.2 V the charging current will be reduced to 0.6 A. The charging end voltage is 14.4 V +/- 0.2. 
LED 4 indicates the charge status.  When the LED is constantly on, the rechargeable battery is full.

 

 

Regeneration mode 

If a deep discharged rechargeable battery is connected to the charger, the regeneration mode is the first mode to start. Pulsing charging currents are used to try 
and bring the deep discharged rechargeable battery to a voltage at which regular recharging function can be started. The maximum time of the regeneration mode 
is 20 minutes. If no adequate battery voltage can be achieved during this time, the charger stops the process, the battery will be detected as defective and LED 3 
is on.  

 

Defective rechargeable batteries/Short-circuit and reversed polarity protection 

The charger recognises defective rechargeable batteries automatically. In this case the selected charging programme will not be started. LED 3 is on. 
Rechargeable batteries with short-circuit respectively with reverse polarity connection will also be detected immediately. In consequence the charging programme 
will not be started. LED 3 flashes.  

 
 

Summary of Contents for PL-C001P

Page 1: ...trieben werden Es darf nicht feucht oder nass werden andernfalls besteht die Gefahr eines lebensgef hrlichen elektrischen Schlages Der Betrieb unter widrigen Umgebungsbedingungen ist unter allen Umst...

Page 2: ...odus eignet sich zum Laden von 6 V Akkus mit einer Kapazit t ab 1 2 Ah bitte beachten Sie die Angaben des Akkuherstellers bez glich des maximalen Ladestroms Dr cken Sie die MODE Taste so oft bis LED 1...

Page 3: ...schutz Dieses Produkt darf am Ende seiner Lebensdauer nicht ber den normalen Haushaltsabfall entsorgt werden sondern muss an einem Sammelpunkt f r das Recycling von elektrischen und elektronischen Ger...

Page 4: ...the risk of a deadly electric shock The use of the product under unfavourable environmental conditions must be avoided under all circumstances Unfavourable environmental conditions include ambient tem...

Page 5: ...Ah please observe the technical data of the battery manufacturer concerning the maximum charging current Press the MODE button again and again until LED 1 flashes After approx 10 seconds the LED is c...

Page 6: ...g Environmental protection note At the end of its useful life this product must not be disposed of together with normal household waste but has to be dropped off at a collection centre for the recycli...

Page 7: ...idifier ni mouiller l appareil dans le cas contraire risque d lectrocution mortelle Evitez imp rativement d utiliser l appareil dans des conditions environnementales d favorables des conditions enviro...

Page 8: ...ci Retirez ensuite les pinces du p le n gatif puis du p le positif DESCRIPTION DES MODES DE FONCTIONNEMENT Mode 6 V 1 Le mode de 6 V est adapt pour charger des batteries d accumulateurs de 6 V une cap...

Page 9: ...e FVA gel Capacit de batterie partir de 1 2 Ah tenir compte des indications du fabricant de la batterie Dimensions 96 x 71 x 73 mm Poids 200 g Remarque concernant la protection de l environnement Lor...

Page 10: ...product mag alleen in droge ruimten binnenshuis worden gebruikt Het mag niet vochtig of nat worden anders bestaat het gevaar van een Gebruik onder ongunstige omgevingsvoorwaarden moet in elk geval wor...

Page 11: ...dus 1 De 6 V modus is geschikt voor het opladen van 6 V accu s met een capaciteit van 1 2 Ah houd a u b rekening met de informatie van de accufabrikant m b t de maximale laadstroom Druk de MODE toets...

Page 12: ...nd met milieubescherming Dit toestel mag aan het eind van zijn levensduur niet met het normale huishoudelijke afval worden meegegeven maar moet op een inzamelpunt voor de recyclage van elektrische en...