Factory values
6 720 642 838 (2010/03)
32
10 Factory values
Access level 0 = customer, 1 = installer
Room temperature
F value
Level
General
No settings for cooling
Circuit 1 Heating
No settings for cooling
Circuit 1 Cooling
Primary cooling circuit
Allow cooling in winter operation
No
1
Outdoor temperature limit for cooling
21 °C
1
Room sensor
None
1
Room temperature
20 °C
1
Room temperature change in cooling
mode
2,0K
1
Cooling/heating change over delay
8h
1
Room temperature hysteresis
1,0K
1
Acknowledge anti-freeze sensor T32
No
1
Anti-freeze limit T32
3 °C
1
Flow sensor
E31.T31
1
Dew point sensor installed
No
1
Minimum set point value T1 at cooling
- With dew point sensor
- Without dew point sensor
10 °C
17 °C
1
1
Regulator settings
- P constant
- I constant
- D constant
- Minimum PID signal
- Maximum PID signal
- Mixing valve running time
1.0
300.0
0.0
0%
100%
300s
1
1
1
1
1
1
Circuit 2, 3...
Mixing valve mode
Off
1
Heat curve
(mixing valve operating mode is Heat-
ing or Heating/Cooling)
Type of heating system
Underfloor
1
Flow temperature at minimum outdoor
temperature
35 °C
1
Parallel offset
0.0K
1
Highest permitted flow temperature T1
40 °C
1
Lowest permitted flow temperature T1
10 °C
1
Cooling
(mixing valve operating mode is Heat-
ing/Cooling or Cooling)
Allow cooling in winter operation
No
1
Outdoor temperature limit for cooling
21,0 °C
1
Room temperature change in cooling
mode
2,0K
1
Cooling/heating change over delay
8h
1
Room temperature hysteresis
1,0K
1
Dew point sensor installed
No
1
Minimum set point value T1 at cooling
17.0 °C
1
Tab. 41 Room temperature, factory settings cooling
External input prim. cooling circuit
Block cooling
No
1
External input circuit 2, 3...
Block cooling
No
1
Tab. 42 External input, factory settings cooling
Outputs
Manual operation time
0min
1
Circulation pumps
Collector circuit pump G3 active in cooling
No
1
Tab. 43 Installer, factory settings cooling