21
20
More information at
www.ivt-hirschau.de
3 years
manufacturer’s warranty. Rechargeable batteries excluded.
GB |
GB |
TECHNICAL SPECIFICATIONS
DSW-300/12 V
DSW-300/24 V
DSW-600/12 V
DSW-600/24V
INPUT
DC rated voltage
12 V
24 V
12 V
24 V
DC voltage range
11 V - 16 V
22 V - 32 V
11 V - 16 V
22 V - 32 V
Rated input current
25 A
12,5 A
50 A
25 A
Deep discharge protection,
idle
10.5 V
21 V
10.5 V
21 V
Deep discharge protection,
rated power
9.5 V
19 V
9.5 V
19 V
Adjustable deep discharge
protection
9 V - 12 V
18 V - 24 V
9 V - 12 V
18 V - 24 V
Early warning deep discharge
protection
1 V before
shutdown
1 V before
shutdown
1 V before
shutdown
1 V before
shutdown
Restart voltage
12.5 V
25 V
12.5 V
25 V
Shutdown, overvoltage
> 16 V
> 32 V
> 16 V
> 32 V
Input power, idle
4 W
4 W
5 W
5 W
Input power, standby
0.4 W
0.4 W
0.4 W
0.4 W
OUTPUT
Output voltage AC (± 2 %)
230 V
eff
230 V
eff
230 V
eff
230 V
eff
Frequency (± 1 %)
50 Hz
50 Hz
50 Hz
50 Hz
Wave form
Pure sinus
Pure sinus
Pure sinus
Pure sinus
Permanent output current
1.3 A
eff
1.3 A
eff
2.6 A
eff
2.6 A
eff
Permanent output power
300 VA
300 VA
600 VA
600 VA
Peak output power
600 VA
600 VA
1200 VA
1200 VA
Power factor
cos
φ
> 0,8
cos
φ
> 0,8
cos
φ
> 0,8
cos
φ
> 0,8
Efficiency
typ. 90 %
typ. 90 %
typ. 90 %
typ. 90 %
Standby level
< 50 VA
< 50 VA
< 70 VA
< 70 VA
GENERAL
Input port
Screw terminals
Screw terminals
Screw terminals
Screw terminals
Output port
Schuko socket®
Schuko socket®
Schuko socket®
Schuko socket®
DC USB output (Type A)
5 V/500 mA
5 V/500 mA
5 V/500 mA
5 V/500 mA
Temperature range, 66 % P
nenn
-25 °C to +60 °C
-25 °C to +60 °C
-25 °C to +60 °C
-25 °C to +60 °C
Temperature range, 100 % P
nenn
-25 °C to +40 °C
-25 °C to +40 °C
-25 °C to +40 °C
-25 °C to +40 °C
Sleep function
activatable
activatable
activatable
activatable
Standby function
activatable
activatable
activatable
activatable
Galvanic isolation
yes
yes
yes
yes
Power start function
yes
yes
yes
yes
E-registration
yes
yes
yes
yes
Remote controlling
yes
yes
yes
yes
Fan cooling
Power /
temperature
controlled
Power /
temperature
controlled
Power /
temperature
controlled
Power /
temperature
controlled
Dimensions (L x W x H)
263 x 164 x 88 mm
263 x 164 x 88 mm
277 x 234 x 88 mm
277 x 234 x 88 mm
Weight
1.8 kg
1.8 kg
2.9 kg
2.9 kg
Part.-No.
430101
430102
430103
430104
OPERATION WITH REMOTE CONTROL
All models of this inverter series may be operated with remote control units.
You may choose between various versions.
Remote switch FS-01, Mounted version (Part.-No. 430111) / FS-02, Integrated version (Part.-No. 43121)
This model is a cable version which is directly connected to the voltage converter. It is equipped with an
on/off switch and two control indicators for DC input and AC output.
Remote control touchscreen cable-connected FB-04 (Part.-No.: 200051)
This model is USB-connected to the voltage converter and is equipped with a colored LC display. The dis-
play serves for both monitoring important values and making adjustments for deep discharge protection.
The remote control is also equipped with a SD card slot. This allows storing important values and easily
transferring them to your PC.
Webbox-LCD (Part.-No.: 200054)
With this additional device it is possible to get access to the inverter over an existing network. The Web-
box offers identical functionalities like the remote control units FB-04.
ADDRESS SETTINGS
The address configuration allows the control and the data evaluation of up to 4 devices
(DSW inverter,
M solar controller)
via remote control
(FB-04/Webbox LCD)
. An address from 1 to 4 is assigned
to the inverter by setting the DIP switches 3 and 4
(see picture)
. The address configuration is only re-
quired, if you intend to operate several devices
(DSW inverter, M solar controller)
by one remote
control.
Address 1
Address 2
Address 3
Address 4
DIGITAL SINUS INVERTER DSW-2000 SYNCHRON
Two DSW-2000 Synchron inverters are connected in
parallel via an additional connection socket and
synchronized to achieve a
permanent output power of
4000 W.
The two inverters can also be operated individually with
the respective continuous output of 2000 W.
All of the other features, technical data and
operation elements correspond to the normal DSW 2000
in the 12 V version.
i
Please use only the synchronous cable supplied by the manufacturer. For connection
observe all hints given in the chapter „CONNECTION”. Turn on both devices after each
other only if you have connected the Synchron connection cable and the DC power
supplies.
Note: Each DSW-2000-Sychron inverter requires its own connection cable set to the
battery for synchronous operation. Please use at least one 50 mm2 wire to connect the
DSW-2000-Synchron 12-V version to the battery because of the high current flow.
Ensure that the DC connection cables are identical.
DSW-2000 Synchron /12 V
(Part.-No.: 430109)
Synchron connection cable 1 m
(Part.-No.: 431007)