9
Tool symbol:
By choosing this symbol you will get to a view, in all real life system parameters will be displayed in an overview. By
touching the
diagram symbol
the right side menu bar of this system parameter window you may switch into the diagram
window. Here you have to possibility to display the daily, monthly and yearly power volume by using the now available
calendar symbol
in the menu bar. With the
return arrow symbol
you may return to the previous view.
Timer function:
After choosing the respective
(DSW or MPPTplus
+
)
in the base menu
,
the time function may be accessed on the right side
of the menu bar. With this an automatic turn on/turn off of the load output may be preselected in a time-dependent
manner. The time selection will be done in 30 minute steps using the graphic symbols on the right side of the menu bar.
Time will be ignored by the device
(NONE)
Define shut off time
(OFF)
Define turn on time
(ON)
Enter the desired time in steps of 30 minutes
Back top previous view
(Return arrow symbol)
USE WITH INVERTERS OF THE DSW SERIES
When using the remote control with inverters of the DSW Series, the following option for operation and adjustment are
available:
Figure 1: Basic menu DSW Figure 2: Setting deep discharge protection
Figure 3: System parameter
In the basic menu the display shows a
battery symbol
, an
inverter symbol
and a
bulb symbol
. Underneath a diagram
displays the real time power on the inverter output related to the time factor.
The
battery symbol
informs you of the current battery status by displaying a full or an empty battery.
When this symbol is being touched, the current battery voltage will be shown. By activating the
check symbol
you will return to the basic menu.
If the
inverter symbol
is being chosen, on the following operation screen (
see figure 2
) the deep discharge
protection threshold
(DISCHARGE)
can be adjusted by using the „+“and „-“buttons.
At a 12 V battery system the adjustment can be made within the range of 9 - 12 V in 0.1 V steps, while at a
24 V battery system the adjustment within the range of 18 - 24 V can be made in 0.2 V steps.
To return to the basic menu the
return symbol
must be used.
By activating the
bulb symbol
a window containing the output parameters of the inverter
(OUTPUT)
will be
opened. This includes the output voltage, the output current and the output power of the connected
alternating current consumer. Additionally this view contains an
ON/OFF symbol
, which allows the manual on/
off switching of the load output via remote control.
By activating the
check symbol
this view may be closed.