background image

21

Settings

Display

Short Description

Reset to factory  
settings

With this setting 
option, all the values 
and parameters can 
be reset to the  
original factory 
settings. 

Note

: All the individ-

ual programs that 
you have generated 
and saved will be 
deleted by this  
function

Important information

For certain settings, the user code (359) is required.

* Some programs are protected by a code. If changes are necessary, the corresponding code 
is provided.  

5.6.2 Information

By pressing the Information key (81), you will reach the information 
screen (the last selected information is displayed). The cursor keys 
(79, 80) can be used to toggle between the possible information. 
This screen can be left with the ESC key (71) or one of the program 
keys (82, 83, ...).

Information

Display

Short Description

Serial number

Serial number of the 
furnace  

Software version

 

Furnace head
Firing hours

 

Furnace operating 
hours

Latest start of the  
calibration program 
UTH 

Date of latest  
calibration of the 
temperature required 
for crystallization.

Latest start of the  
calibration program 
MTH

Date of latest  
calibration of the 
temperature required 
for sintering.

Calibration value UHT

Calibration value at 
880°C/1616°F. The 
value is displayed in 
accordance with the 
selected temperature 
mode in °C or °F.

Calibration value 
MHT

Calibration value at 
1500°C/2732°F. The 
value is displayed in 
accordance with the 
selected temperature 
mode in °C or °F.

Information

Display

Short Description

Mains voltage

Shows the current 
mains voltage

Error list

Enables the display of 
the latest error  
messages.

5.7  Explanation of the display symbols

Symbol name

Meaning

Symbol

Open furnace head

Shown in the  
recommendation area, 
where the next most likely 
action is suggested.

Close furnace head

Shown in the  
recommendation area, 
where the next most likely 
action is suggested.

Press START

Shown in the  
recommendation area, 
where the next most likely 
action is suggested.

 

Press STOP

Shown in the  
recommendation area, 
where a possible action is 
suggested.

 

Press ENTER

Shown in the  
recommendation area, 
where a possible action is 
suggested.

Press ESC

Shown in the  
recommendation area, 
where a possible action is 
suggested.

Use cursor keys

Shown in the  
recommendation area, 
where a possible action is 
suggested.

Use – / + keys

Shown in the  
recommendation area, 
where a possible action is 
suggested.

General write  
protection

Shows in the parameter 
list that the general write 
protection for all programs 
has been activated by 
means of the user code.

Individual write  
protection active

Shows in the parameter 
list that the individual 
write protection for this 
program is active.

Individual write  
protection not active

Shows in the parameter 
list that this program is 
not write-protected.

Summary of Contents for Programat CS4

Page 1: ...Programat CS4 Operating Instructions...

Page 2: ......

Page 3: ...5 5 Settable parameters and possible value ranges 5 6 Settings test programs and information 5 7 Explanation of the display symbols 5 8 Explanation of the acoustic signals 5 9 OSD 6 Practical Use 23 6...

Page 4: ...nics plug 24 Leave spring 25 Air vents base 26 Cooling tray 27 Cooling tray fastening screw 28 Silicone washer 29 Hood 30 Attachment screw for hood 31 Air vents furnace head 32 Air vents rear panel 33...

Page 5: ...5 44 16 26 4 8 27 28 15 25 1 3 6 5 37 7...

Page 6: ...6 39 17 22 18 23 21 20 9 38 46 47 19 24 35 9 10 11 10 11 14 31 30 29 42 45 13 12 32 42...

Page 7: ...key 81 Information key 82 Program 1 key 83 Program 2 key 84 Program 3 key 85 Program 4 key 86 Next program key 87 Open furnace head 88 Close furnace head 100 Sinter tray 102 Cleaning brush 103 IPS e m...

Page 8: ...crushing The Operating Instructions must be read 1 3 Notes regarding the Operating Instructions Apparatus Programat CS4 Target group Dentists dental professionals These Operating Instructions facilit...

Page 9: ...ust be operated under the indicated environmental and operating conditions see chapter 9 The Programat CS4 must be properly maintained Do not use colouring liquids containing chlorine or hydro chloric...

Page 10: ...ace 2 1 10 Contraindication Do not insert any foreign objects into the air vents There is a risk of electric shock 2 1 11 Burn hazard Never place objects in the hot firing chamber by hand since there...

Page 11: ...ks and dangers may perform these procedures After maintenance the required safety tests high voltage resistance protective conductor etc have to be carried out Ensure that only fuses of the indicated...

Page 12: ...uctor Protection from electric shock Electric fuses Protection from electric shock Furnace housing and end caps Protection from electric shock burning and crushing 3 3 Description of functions The sin...

Page 13: ...2 4 5 2 3 4 5 3 1 5 2 3 4 5 3 4 2 Selecting the location Place the furnace on a fire proof flat table using the rubber feet Make sure that the furnace is not placed in the immediate vicinity of heater...

Page 14: ...strongly against the rear of the furnace For safety reasons the spacer must always be mounted Secure the cooling tray 26 with the two screws 27 including the silicone washers 28 Place the cooling tra...

Page 15: ...er on the furnace head and carefully position it on the furnace head mounting 35 Ensure that the furnace head mounting mark 33 is aligned with the furnace base mounting mark 34 Make sure that the sint...

Page 16: ...tablishing additional connections Power connection Please make sure that the voltage indicated on the rating plate complies with the local power supply Connect the power cord 12 with the power socket...

Page 17: ...1 Connect the power cord 12 with the wall socket 2 Put the On Off switch 9 at the rear of the furnace on position I Subsequently the furnace conducts an automatic self test The performance of all furn...

Page 18: ...tarts the selected program Start LED 74 Lights up once a program has started It flashes when the program is paused Stop key 75 Pressing 1 x pause program Pressing 2 x program is aborted The STOP key a...

Page 19: ...ive error number is indicated Value range C Value range F Symbol Parameters min max Unit min max Unit v1 Predrying stage 1 Predrying temperature 0 100 300 C 0 212 572 F V1 Predrying time 00 00 00 20 h...

Page 20: ...red volume can be set using the keys Melody The desired melody may be set using the keys Programming Enables the programming of the parameters for the currently selected program Settings Display Short...

Page 21: ...C or F Calibration value MHT Calibration value at 1500 C 2732 F The value is displayed in accordance with the selected temperature mode in C or F Information Display Short Description Mains voltage Sh...

Page 22: ...ith the error tune endless beep The beeper may be switched off with the STOP key while the error message still remains visible If the error message is acknowledged with ESC the beeper also stops At th...

Page 23: ...2 Loading for sintering procedure The sinter tray 100 holds up to approximately 6 units depending on the program Make sure that the objects do not touch in order to prevent them from sintering togeth...

Page 24: ...icates a temperature below 400 C 752 F Step 2 Open the furnace head using the open furnace head key 87 Use a sinter tray fork to place the loaded sinter tray into the furnace Step 3 Press the Start ke...

Page 25: ...a Settings Renaming the keyboard can be selected provided the currently selected program is not write protected The desired letters can be selected using the cursor keys circular The letter is selecte...

Page 26: ...rticles see image a Fine glass dust The insulation of the lower part of the furnace and the cooling tray show residue of fine glass dust This type of contamination is more difficult to discern 7 1 2 C...

Page 27: ...be cleaned from time to time What When Cleaning material Furnace housing 7 and furnace head if required soft dry cloth Membrane sealed keypad 8 weekly soft dry cloth Cooling tray 26 daily cleaning bru...

Page 28: ...UTH 1 Press the Settings key 78 to access the Settings screen Select Temperature Calibration UTH using the cursor keys 79 80 The following display appears The UTH calibration program is selected with...

Page 29: ...correction value can be transferred to the furnace with the help of the keys Each keystroke changes the furnace temperature by 1 C The correction value must be added to the current temperature of the...

Page 30: ...oltage The furnace is operated with the incorrect supply voltage Make sure that the furnace is operated with the supply voltage indicated on the rating plate 1310 Calibration reminder Some time has pa...

Page 31: ...ement bent or fractured Switch off the furnace and contact the Ivoclar Vivadent After Sales Service Damage of the thermocouple Is the thermocouple damaged or fractured Contact the Ivoclar Vivadent Aft...

Page 32: ...kg Furnace head 17 kg Safety notes The sinter furnace complies with the following standards IEC 61010 1 2010 EN 61010 1 2010 UL 61010 1 2012 2015 CSA 61010 1 2012 2015 IEC 61010 2 010 2014 EN 61010 2...

Page 33: ...contact the Ivoclar Vivadent Service Center Important information The current program tables are also available at www ivoclarvivadent com The program tables can be downloaded from the Internet as PDF...

Page 34: ......

Page 35: ......

Page 36: ...ivadent S A de C V Calzada de Tlalpan 564 Col Moderna Del Benito Ju rez 03810 M xico D F M xico Tel 52 55 50 62 10 00 Fax 52 55 50 62 10 29 www ivoclarvivadent com mx Ivoclar Vivadent BV De Fruittuine...