background image

Version: 1
Date information prepared: 2021-04 
Valid from software V7.0

The apparatus has been developed solely for use in dentistry. Start-up and operation should 
be carried out strictly according to the Operating Instructions. Liability cannot be accepted 
for damages resulting from misuse or failure to observe the Instructions. The user is solely 
responsible for testing the apparatus for its suitability for any purpose not explicitly stated in 
the Instructions. Descriptions and data constitute no warranty of attributes and are not 
binding.

© Ivoclar Vivadent AG, Schaan/Liechtenstein
web/en

Ivoclar Vivadent – worldwide

Ivoclar Vivadent AG

Bendererstrasse 2
9494 Schaan
Liechtenstein
Tel. +423 235 35 35
Fax +423 235 33 60
www.ivoclarvivadent.com

Ivoclar Vivadent Pty. Ltd. 

1 – 5 Overseas Drive
P.O. Box 367
Noble Park, Vic. 3174
Australia
Tel. +61 3 9795 9599
Fax +61 3 9795 9645
www.ivoclarvivadent.com.au

Ivoclar Vivadent GmbH

Tech Gate Vienna
Donau-City-Strasse 1
1220 Wien
Austria 
Tel. +43 1 263 191 10
Fax +43 1 263 191 111
www.ivoclarvivadent.at

Ivoclar Vivadent Ltda.

Alameda Caiapós, 723
Centro Empresarial Tamboré
CEP 06460-110 Barueri – SP
Brazil
Tel. +55 11 2424 7400
www.ivoclarvivadent.com.br

Ivoclar Vivadent Inc.

1-6600 Dixie Road
Mississauga, Ontario
L5T 2Y2
Canada
Tel. +1 905 670 8499
Fax +1 905 670 3102
www.ivoclarvivadent.us

Ivoclar Vivadent Shanghai 
Trading Co., Ltd.

2/F Building 1, 881 Wuding Road, 
Jing An District 
200040 Shanghai 
China
Tel. +86 21 6032 1657
Fax +86 21 6176 0968
www.ivoclarvivadent.com

Ivoclar Vivadent Marketing Ltd.

Calle 134 No. 7-B-83, Of. 520
Bogotá
Colombia
Tel. +57 1 627 3399
Fax +57 1 633 1663
www.ivoclarvivadent.co 

Ivoclar Vivadent SAS

B.P. 118
74410 Saint-Jorioz
France
Tel. +33 4 50 88 64 00
Fax +33 4 50 68 91 52
www.ivoclarvivadent.fr

Ivoclar Vivadent GmbH 

Dr. Adolf-Schneider-Str. 2
73479 Ellwangen, Jagst
Germany
Tel. +49 7961 889 0
Fax +49 7961 6326
www.ivoclarvivadent.de

Ivoclar Vivadent Marketing (India) 
Pvt. Ltd. 

503/504 Raheja Plaza 
15 B Shah Industrial Estate 
Veera Desai Road, Andheri (West) 
Mumbai, 400 053 
India
Tel. +91 22 2673 0302 
Fax +91 22 2673 0301
www.ivoclarvivadent.in

Ivoclar Vivadent Marketing Ltd.

The Icon
Horizon Broadway BSD
Block M5 No. 1
Kecamatan Cisauk Kelurahan Sampora
15345 Tangerang Selatan – Banten
Indonesia
Tel. +62 21 3003 2932
Fax +62 21 3003 2934
www.ivoclarvivadent.com

Ivoclar Vivadent s.r.l. 

Via del Lavoro 47
40033 Casalecchio di Reno (BO)
Italy
Tel. +39 051 6113555
Fax +39 051 6113565
www.ivoclarvivadent.it

Ivoclar Vivadent K.K.

1-28-24-4F Hongo
Bunkyo-ku 
Tokyo 113-0033
Japan
Tel. +81 3 6801 1301
Fax +81 3 5844 3657
www.ivoclarvivadent.jp

Ivoclar Vivadent Ltd.

4F TAMIYA Bldg.
215 Baumoe-ro, Seocho-gu
Seoul, 06740
Republic of Korea
Tel. +82 2 536 0714
Fax +82 2 6499 0744
www.ivoclarvivadent.co.kr

Ivoclar Vivadent S.A. de C.V.

Calzada de Tlalpan 564,
Col Moderna, Del Benito Juárez
03810 México, D.F.
México
Tel. +52 (55) 50 62 10 00
Fax +52 (55) 50 62 10 29
www.ivoclarvivadent.com.mx

Ivoclar Vivadent BV

De Fruittuinen 32
2132 NZ Hoofddorp
Netherlands
Tel. +31 23 529 3791
Fax +31 23 555 4504
www.ivoclarvivadent.com

Ivoclar Vivadent Ltd.

12 Omega St, Rosedale
PO Box 303011 North Harbour
Auckland 075, New Zealand
Tel. +64 9 914 9999
Fax +64 9 914 9990
www.ivoclarvivadent.co.nz

Ivoclar Vivadent Polska Sp. z o.o.

Al. Jana Pawła II 78
00-175 Warszawa, Poland
Tel. +48 22 635 5496
Fax +48 22 635 5469
www.ivoclarvivadent.pl

Ivoclar Vivadent LLC 

Prospekt Andropova 18 korp. 6/  
office 10-06, 115432 Moscow 
Russia 
Tel. +7 499 418 0300 
Fax +7 499 418 0310 
www.ivoclarvivadent.ru

 

Ivoclar Vivadent Marketing Ltd.

Qlaya Main St.
Siricon Building No.14, 2

nd

 Floor

Office No. 204, P.O. Box 300146
Riyadh 11372, Saudi Arabia
Tel. +966 11 293 8345
Fax +966 11 293 8344
www.ivoclarvivadent.com

Ivoclar Vivadent S.L.U.

Carretera de Fuencarral nº24
Portal 1 – Planta Baja
28108-Alcobendas (Madrid)
Spain
Tel. +34 91 375 78 20
Fax +34 91 375 78 38
www.ivoclarvivadent.es

Ivoclar Vivadent AB

Gustav III:s Boulevard 50
169 74 Solna
Sweden
Tel. +46 8 514 939 30
Fax +46 8 514 939 40
www.ivoclarvivadent.se

Ivoclar Vivadent Liaison Office

: Tesvikiye Mahallesi 
Sakayik Sokak
Nisantas’ Plaza No:38/2
Kat:5 Daire:24 
34021 Sisli – Istanbul 
Turkey 
Tel. +90 212 343 0802 
Fax +90 212 343 0842
www.ivoclarvivadent.com

Ivoclar Vivadent Limited

Compass Building
Feldspar Close
Warrens Business Park
Enderby
Leicester LE19 4SD
United Kingdom
Tel. +44 116 284 7880
Fax +44 116 284 7881
www.ivoclarvivadent.co.uk

Ivoclar Vivadent, Inc. 

175 Pineview Drive
Amherst, N.Y. 14228
USA
Tel. +1 800 533 6825
Fax +1 716 691 2285
www.ivoclarvivadent.us

Summary of Contents for 747826BU

Page 1: ...Programat P510 G2 Operating Instructions Valid from Software V7 0...

Page 2: ...2 Declaration of conformity...

Page 3: ...n to the operation 23 5 2 Firing programs and programming options 26 5 3 Managing programs 38 5 4 Advanced functions of the furnace Software update 42 5 5 Multimedia functions 56 5 6 Digital Shade Ass...

Page 4: ...Status Display OSD 13 Operating unit fixture 14 USB connections 15 Card reader 2 Cooling tray 4 Audio ports in out 3 Housing base 16 Cover for head opening mechanism 17 Air vents base 18 USB connectio...

Page 5: ...g muffle 26 Furnace head sealing ring 28 Sealing surface 27 Infrared camera 38 Screw for connection cover 39 Air vents rear panel 40 Heating element fuse 41 Vacuum hose connection 42 Vacuum hose 29 On...

Page 6: ...uple plug socket 53 Furnace head vacuum connection 43 Furnace head mounting 44 Furnace head release 49 Heater plug 50 Heater plug socket List of parts 60 LAN download cable 61 Programat Firing Tray Ki...

Page 7: ...uctions The signs and symbols in these Operating Instructions facilitate the finding of important points and have the following meanings Symbol Note Risks and dangers Important information Contraindic...

Page 8: ...voltage range shown on the images e g rating plate may differ depending on the voltage version of your furnace 1 5 Notes on the images in the Operating Instructions All images and illustrations in th...

Page 9: ...ions to assure proper use of the furnace The instructions regulations and notes in these Operating Instructions must be observed The instructions regulations and notes in the material s Instructions f...

Page 10: ...damaged There is a risk of electric shock upon contact with the heating wire Avoid damage of the insulation by contact with the investment tongs or firing tongs Contraindication Firing trays must not...

Page 11: ...ntains ceramic fibres and may release fibre dust Do not use compressed air or blow on the furnace thus distributing the dust in the environment and observe the additional notes on page 13 Risk of crus...

Page 12: ...soft cloth Do not use any solvents Disconnect power before cleaning and allow the furnace to cool down The furnace must be cool before it is packed for transportation purposes Use original packaging f...

Page 13: ...t Fibre dust has proved to be carcinogenic in animal experiments The heating muffle may only be dismounted by a qualified After Sales Service Centre Information regarding the Safety Data Sheet is also...

Page 14: ...P510 G2 consists of the following components Furnace base with electronic controls Furnace head with firing chamber Cooling tray Firing table Power cord and hose for vacuum pump 3 2 Hazardous areas a...

Page 15: ...sing contact your local Ivoclar Vivadent Service Centre We recommend keeping the original packaging for future service and transportation purposes 4 2 Selecting the location Place the furnace on a fla...

Page 16: ...he two fastening screws 1 of the cooling tray and the transport protection of the infrared camera Secure the cooling tray 2 with the two screws 1 Step 2 Mounting the firing plate Place the firing plat...

Page 17: ...cables of the furnace head with the furnace base Proceed as follows Connect the vacuum hose 53 Insert the thermocouple plug 51 Make sure that the polarity of the plug is correct Insert the heater plu...

Page 18: ...mum length of the vacuum hose is 1 6 m Step 6 Mounting the connection cover Mount the connection cover 37 and secure it with the fastening screw 38 Make sure that the lateral catch springs snap into p...

Page 19: ...uum hose 53 7 Press the leaf spring 44 with a finger lift off the furnace head at the same time and remove it Make sure the furnace head has completely cooled down before it is removed fire hazard 4 5...

Page 20: ...e Next button is used to reach the next entry screen Step 1 Select the language The first setting is the language selections The touch buttons display keys can be operated by tapping the display Selec...

Page 21: ...tion about the privacy policy can be found at http www ivoclarvivadent com digitalservices The Next button is used to reach the next entry screen Step 5 Select the date format Confirm the entry with t...

Page 22: ...power supply voltage is in the acceptable range The power supply is outside the acceptable range Software version The currently installed software version is displayed 4 Installation and Initial Start...

Page 23: ...ction Home Switch to home screen main menu Program key Press once Display of the currently selected program Press twice Switch to the program selection via number entry IRT key With this key the infra...

Page 24: ...ot in the acceptable range Cancel entry The entry can be cancelled with this button changed values are not saved Program parameter buttons Pressing these buttons allows you to change program parameter...

Page 25: ...completed To inform the user that the automatic self test has been successfully completed a pre set not modifiable melody is played Furnace head open and temperature below 560 C To inform the user tha...

Page 26: ...or Ivoclar Vivadent materials b 500 free individually adjustable programs b 500 free individually adjustable programs on a USB stick The program types are subdivided into program groups Each group con...

Page 27: ...s in free programs are NOT reset to the factory settings or changed 5 2 2 Program selection The program selection requires only few steps 1 Select program type 3 Select the program 4 Start program or...

Page 28: ...nged The following information is displayed 1 Information bar Program designation Current furnace temperature 2 Firing curve Closing time holding time Temperature increase rate holding temperature lon...

Page 29: ...he Options button 2 Press the Deactivate write protection button 3 Press the Close button to leave the Options menu 5 Operation and Configuration Changing program options Pressing the Options button o...

Page 30: ...ture button 3 Enter the desired predrying temperature and confirm with the green button 4 The predrying temperature was successfully changed Press the Close button to leave the Options menu The progra...

Page 31: ...of the parameters The furnace is equipped with an automatic plausibility check function The parameters are checked upon each program start In case of contradictory parameter combinations the program s...

Page 32: ...ong term cooling Value range C OFF or 1 1200 C Value range F 0 or 34 2192 F Long term cooling If long term cooling is activated the furnace cools to the set temperature L at the end of the holding tim...

Page 33: ...d to a stand by temperature of 403 C in the factory The temperature can be individually set for each program Value range C 100 700 C Value range F 212 1292 F Two stage programs If this function is act...

Page 34: ...ter the pre vacuum time is over The value V1 is ignored upon the start of a program with individually activated pre vacuum The vacuum remains switched on until V2 is reached V2 must be higher than the...

Page 35: ...operating mode is the preferred and recommended operating mode for standard veneer and all ceramic firing processes If the IRT operating mode is selected the infrared camera controls the predrying an...

Page 36: ...the form of a firing curve The estimated remaining time is also displayed in 10 second intervals If no vacuum is activated the vacuum indicator and all the corresponding parameters are blank The proc...

Page 37: ...f the Display button is pressed while the firing curve is displayed the remaining time will be shown The remaining time indicator informs the user about the time that is left until the process is comp...

Page 38: ...paused the display shows a flashing Pause and the indicator changes back to the program screen If a program is stopped prematurely Vacuum release is shown in the display during the flooding of the fi...

Page 39: ...ocess 5 3 1 Copy programs With the copy wizard individual programs program groups and program sectors can be copied The source and target of the copy process can be selected in the copy assistant Prog...

Page 40: ...he product brand for the current group can be selected 1 Press the corresponding button in the Admin menu 2 Select the desired product brand Confirm the entry with the green button 5 3 2 Reset program...

Page 41: ...can be renamed only possible for individual programs 1 Press the corresponding button in the Admin menu and select whether the program name or group name should be changed 2 Enter the desired program...

Page 42: ...lay 4 Select the desired display brightness in percent and confirm the entry with the green button or cancel the entry with the red button The setting was changed To return to the home screen press ei...

Page 43: ...time Setting options hh mm ss Date Set the current date Setting options according to the set date format Date format Set the date format Setting options dd mm yyyy mm dd yyyy Time zone Set the respec...

Page 44: ...tion interval Set the notification as to when the next calibration should be conducted Setting options 1 3 6 12 months Resetting heating muffle firing hours to zero If this function is executed the he...

Page 45: ...tion of the furnace Operating hours Number of operating hours 5 Operation and Configuration Testing push notifications Here push notifications for communicating with the Programat app can be tested Th...

Page 46: ...utorials Display of the QR code to access the video tutorials 5 4 3 Temperature calibration The sheathed thermocouple and heating muffle of the furnace may be subject to changes which affect the furna...

Page 47: ...ation failed The calibration value is the difference between the measured current temperature and the desired set temperature At the end of the program open the furnace head and carefully remove the A...

Page 48: ...nction individual programs and settings can be backed up on a USB flash drive We recommend using this feature e g before a software update or before sending in the furnace for maintenance purposes Mor...

Page 49: ...modified Ivoclar Vivadent programs may be overwritten during a software update Individual programs are not affected and will not be overwritten 5 4 5 Software Update Software updates can be easily in...

Page 50: ...bject in the chamber e g firing tray may influence the test result Conduct the heater test immediately after switching on the furnace and before any actual firing procedures are conducted If the furna...

Page 51: ...agnostic button in the Diagnosis menu 2 Generate a diagnostic file Connect a USB stick with the furnace Press the Execute button 3 Once the diagnostic file has been generated one of the following mess...

Page 52: ...of water in the insulation of the firing chamber and the vacuum pump will result in a lower vacuum and thus in impaired firing results For that reason the furnace head should be kept closed when the...

Page 53: ...arious operating modes can be selected This increases the reliability of use and adjusts the furnace to the area of application The following modes are available Standard All functions of the ceramic...

Page 54: ...he green button 4 Program screen in the Production operating mode example 2 Enter the user code Enter the user code and confirm the entry with the green button The Protected or Production modes can be...

Page 55: ...the desired network 4 Enter the WLAN password and confirm with the green button or abort the entry with the red button 5 The WLAN connection was successfully set up After the initial set up of the WLA...

Page 56: ...ing data must be connected 5 5 1 Image display Scroll to page 2 in the home screen and press the Images button 1 Select folder The arrow keys are used to scroll through the folder The folder can be op...

Page 57: ...enlarge or the lower left downsize 8 Moving the image An enlarged image can be moved in all directions For that purpose press the touch screen with the finger and move the image in the desired directi...

Page 58: ...e playback can only be stopped by pressing the corresponding button in the media player see Step 2 5 5 3 Video player Scroll to page 2 in the home screen and press the Video button 1 Selecting the fol...

Page 59: ...sponding button is used to adjust the volume of the playback 6 Switch to full screen view The corresponding button is used to switch to the full screen view 7 Full screen view The corresponding button...

Page 60: ...on The folder can be left by clicking the Back button The image displayed can be deleted by clicking the Delete button The analysis of the displayed image can be started by pressing the green button 1...

Page 61: ...es the tooth to be analyzed with the reference teeth The result of the shade analysis is shown directly on the tooth to be analyzed as well as on the right side of the screen shade B1 in this example...

Page 62: ...ull screen view By double clicking the touch screen the image section can be enlarged and reduced again 7 Verifying the designations correcting If the designations of the shade guide teeth cannot be c...

Page 63: ...can be saved as a log file by tapping the Disk button The log file can be printed via the PrograBase X10 software or stored as a PDF file 10 Log function The current shade analysis can be saved as a l...

Page 64: ...h on Switch on the furnace with the mains switch at the rear of the furnace The furnace conducts an automatic self test Wait until the furnace has reached the set stand by temperature and or the Optic...

Page 65: ...urve display The IRT key see Chapter 5 1 2 is used to switch to the view of the infrared camera during the closing and predrying process The corresponding key is pressed again to return to the firing...

Page 66: ...self test Wait until the furnace has reached the set stand by temperature Step 2 Select the program After the self test the display shows the home screen Press the Individual Programs button Step 3 En...

Page 67: ...logy active position the objects in such a way that the infrared camera has a wide view of the objects Use the markings on the frame plate see Figure for orientation purposes The IRT key see Chapter 5...

Page 68: ...metal frameworks with a metal margin or a holding pin have to be placed in such a way that the metal margin or the holding pin is not caught by the infrared camera as this may affect the correct tempe...

Page 69: ...furnace head and furnace base are clean and undamaged Sealing rims of the furnace head and the furnace base weekly Check the membrane sealed keypad for visible damage If the key pad is damaged it has...

Page 70: ...Vivadent After Sales Service if necessary 7 4 Stand by We recommend keeping the furnace head closed especially if the temperature drops below 150 C If the furnace head is open there is a risk that the...

Page 71: ...14 Temperature in the firing chamber 410 C at the start of the calibration program i e too high Temperature too high for calibration Furnace is cooling down Try restarting the program later 16 T2 T1 E...

Page 72: ...ion Sample might be incorrectly inserted Try again with a new sample and make sure the sample shows the correct contact 1501 yes Hint working hours The heating muffle has working hours Please perform...

Page 73: ...used The height of the firing tray must correspond with the height of the firing trays recommended for the respective materials by Ivoclar Vivadent AG 2761 yes Error IRT Check the orientation and posi...

Page 74: ...tart dehumidification program Incorrect or illogical temperature indication Is the thermocouple bent or fractured Contact your local Ivoclar Vivadent Service Centre Is the thermocouple correctly conne...

Page 75: ...resetting to factory settings In this process all programs melodies screens images and volume adjustments are irrevocably reset to the factory settings For that purpose proceed as follows 1 Open Sett...

Page 76: ...ettings The following messages are displayed Reset to factory settings successful Reset to factory settings failed To return to the home screen press either the touch button Home in the navigation bar...

Page 77: ...le voltage fluctuations 10 Max power consumption 14 A at 100 V 12 A at 110 120 V 8 5 A at 200 240 V Acceptable data for pumps of other manufacturers Max output Final vacuum 250 W max leakage current 0...

Page 78: ...ions Acceptable ambient temperature range 5 C to 40 C Acceptable humidity range Maximum relative humidity 80 for temperatures up to 31 C gradually decreasing to 50 relative humidity at 40 C condensati...

Page 79: ...Centre Important information The current program table is also available at www ivoclarvivadent com downloadcenter The program tables can be downloaded from the internet as PDF files Please make sure...

Page 80: ...roadway BSD Block M5 No 1 Kecamatan Cisauk Kelurahan Sampora 15345 Tangerang Selatan Banten Indonesia Tel 62 21 3003 2932 Fax 62 21 3003 2934 www ivoclarvivadent com Ivoclar Vivadent s r l Via del Lav...

Reviews: