25
– Selection list
In the selection list, the desired parameter can be selected by using the up/down
arrows. An entry must be confirmed with the green button. After that, the
selection list is closed.
The selection list can be closed with the red button, without any parameters
being changed.
5.1.5 Explanation of the home screen
After the furnace is switched on, the display shows the home screen. All functions of the Programat can be selected from
this screen. You can switch back to the home screen with the
[Home]
button.
By pressing a selection button, you will reach the corresponding menu
(e.g. firing programs, settings, calibration, etc.).
The next page of the home screen can be accessed with the
[Arrow]
button, where additional functions are available.
The circles between the arrows indicate the number of pages.
The current page is marked with a light dot.
5.1.6 Explanation of the speaker signals
– Upon closing the furnace head below 100 °C
There is a risk of crushing upon closing the furnace head. If the furnace head is closed below 100 °C, the user
is alerted to the hazard by an acoustic signal.
– After the self-test is completed
To inform the user that the automatic self-test has been successfully completed, a pre-set, not modifiable melody is
played.
– Furnace head open and temperature below 560 °C
To inform the user that the temperature in the open furnace head has dropped below 560°C, the selected melody is
played (5 seconds). In other words, the furnace head is basically cool enough for the next program start. The acoustic
signal can be stopped by pressing STOP.
– Furnace head open and temperature below 360 °C
To inform the user that the temperature in the open furnace head has dropped below 360 °C, the selected melody is
played. If the first playback (10 seconds) is not acknowledged with the STOP key, a second playback sounds after
5 minutes (for 5 minutes) to signal that the furnace head is cooling down. After that, no further signal is played.
If one of the two playbacks is acknowledged with the STOP key, the signal transmitter is switched off and no further
signals will be sounded.
– For error messages
Error messages are acoustically supported with the “error melody” (endless beep). The signal transmitter may be
switched off with the STOP key, while the error message still remains visible. If the error message is acknowledged with
the corresponding button, the signal transmitter is also switched off.
5. Operation and Configuration