1. 

POWER:

 Press the 

POWER 

button once to manually turn the portable air conditioner on. Press it again to turn 

 

the unit off. 

2. 

MODE: 

Press the 

MODE 

button to cycle through the different mode options. The corresponding indicator icons 

 

will light up on the LCD display. The available modes are as follows: Air Conditioning mode (

COOL

), Fan Only 

 mode 

(

FAN

), Dehumidifier mode (

DRY

), Sleep mode (

SLEEP

), and Auto mode (

AUTO

). 

 

NOTE: The exhaust hose and window kit must be installed in order to use the unit in air conditioner, dehumidifier, 

 

auto, and sleep modes. When using this device in fan-only mode, however, the window kit is not required.

3. 

FAN SPEED:

 Press the 

FAN HIGH

FAN MED

, or 

FAN LOW

 buttons to choose your desired fan speed. 

 

NOTE: When the unit is in dehumidifier mode, the fan speed cannot be changed; when Turbo Cool mode is 

 

activated, the fan speed will automatically be set on high and cannot be changed during that time.

4. 

TEMP:

 Set your desired temperature by pressing the 

 or 

 buttons while the unit is in air conditioning mode. 

 

The temperature readout on the LCD display of the remote will increase or decrease accordingly. 

 

NOTE: The temperature will be displayed in degrees Fahrenheit. To switch between Fahrenheit and Celsius, press 

 the 

°C/°F 

button.

5. 

SLEEP MODE:

 To put the air conditioner into sleep mode, press the 

SLEEP 

button on the remote control while 

 

the unit is in air conditioning mode. The SLEEP icon will appear on the remote LCD screen. While in sleep mode, 

 

the fan will run on LOW to keep noise at a minimum, and the set temperature will gradually increase to 2°F above 

 

the temperature you originally set during the first two hours. After two hours, the unit will then continue to 

 

operate at the same temperature until sleep mode is deactivated by pressing the 

SLEEP 

button again.

6. 

TIMER: 

Press the 

TIMER 

button while the unit is powered on to set a time until it automatically turns off. Pressing 

 

it while the unit is plugged in but powered off will set a time until it automatically turns on. The hour indicator on 

 

the LCD screen will turn on. Use the 

 and 

 buttons to set the duration of the timer in hours (from 1-24). To 

 

cancel the timer, press the TIMER button and hold it until the timer icon at the bottom of the LCD screen turns off.

7. 

TURBO COOL: 

Press the 

TURBO COOL

 button to set the air conditioner to cool at a temperature setting of 61°F 

 

(16.1°C) with the fan on high for ten (10) minutes and then return to the original settings. Fan speed is not 

 

adjustable in this mode.

 

NOTE: If the unit has been in fan mode for less than three (3) minutes and you attempt to switch it to Turbo Cool, it 

 

will cause a compressor protection shutdown, and you will need to wait three minutes for the compressor to come 

 back 

on.

8. 

MY TEMP:

 Press the 

MY TEMP

 button to switch the thermostat sensor from the static location in the air 

 

conditioning unit to the location of the remote control. The air conditioner will then cool according to the 

 

temperature at the remote control’s location. (This is helpful in larger/oddly shaped rooms.)

9. 

CHILD LOCK:

 Press this button to lock the remote control buttons. Press it again to unlock the buttons.

OPERATING INSTRUCTIONS

Air Conditioning Mode

1.  Install the exhaust hose and window kit properly. (See pages 5–6)

 

NOTE: This step is required in order for the air conditioner to function.

2.  Plug the power cord into an electrical outlet.

3. Press 

the 

POWER 

button to turn on the unit.

4. Press 

the 

MODE 

button until the air conditioner mode indicator (

COOL

) lights up on the control panel display or 

 

the remote LCD screen.

5. Press 

the 

+

 or 

 buttons (

 and 

 on the remote) until your desired room temperature appears on the display. 

 

This unit’s temperature range is from 61°F – 88°F.

6.  Set the desired fan speed by pressing the 

FAN SPEED

 button on the control panel to cycle between speed 

 

options, or by pressing the 

FAN HIGH

/

FAN MED

/

FAN LOW

 buttons on the remote control.

 

NOTE: On hot days, the most efficient way to cool a room will be to set the temperature on the lowest setting and 

 

the fan speed on high. Reducing the length of the exhaust duct, insulating the exhaust hose and window kit, and 

 

keeping direct sunlight in the room to a minimum will also improve cooling efficiency.

Summary of Contents for IVAPAC12BTU

Page 1: ...product and retain this guide for reference This product is intended for domestic use only This product is covered by a limited one year warranty Coverage is subject to limits and exclusions See warr...

Page 2: ...R button or the TIMER function to turn this unit on or off Never use this unit in an area subject to excessive moisture or humidity or in the immediate surroundings of a bath shower swimming pool or s...

Page 3: ...button while the air conditioner is in operation 2 DO NOT use the TEST and RESET buttons as ON and OFF switches 3 The cord and plug are not intended to offer protection to externally connected loads o...

Page 4: ...Opening 8 Air Intake Grille 9 Condensation Drainage Hole WINDOW KIT 10 16 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter Grille 13 13a Window Kit Adapter 14 Optional Window Kit Adapte...

Page 5: ...installed in sliding windows and sliding glass doors up to 7 2 13 m long When installing the window kit make sure to keep the exhaust hose as short and straight as possible for maximum efficiency Asse...

Page 6: ...mark the kit and cut one end down to properly t the opening 2 Screw the exhaust hose connector 11 onto the exhaust hose 10 as shown 4 Attach the exhaust hose 10 to the window kit adapter 13 13a and th...

Page 7: ...s not required 3 TEMP Set your desired temperature by pressing the or buttons while the unit is in air conditioning mode The temperature indicator LED will ash the temperature while it is being adjust...

Page 8: ...t adjustable in this mode 7 BUCKET FULL When this air conditioner cannot evaporate the collected moisture fast enough the excess water collects in a backup water tank located inside the unit This wate...

Page 9: ...The hour indicator on the LCD screen will turn on Use the and buttons to set the duration of the timer in hours from 1 24 To cancel the timer press the TIMER button and hold it until the timer icon a...

Page 10: ...lectrical outlet 3 Press the POWER button to turn on the unit 4 Press the MODE button until the auto mode indicator AUTO lights up on the control panel display or the remote LCD screen Sleep Mode In s...

Page 11: ...the excess hose length 5 Make sure there are no kinks or knots in the garden hose as shown below 6 When you turn the air conditioner on gravity will help drain the water from the internal water tank...

Page 12: ...sport 1 Empty any excess water by unplugging the drain plug in the back of the unit as described on page 11 2 Unplug the unit 3 Store or transport the unit in a cool dry place TROUBLESHOOTING Problem...

Page 13: ...Power Source 115 V 60 Hz 115 V 60 Hz Noise Level Noise Level 55 dB A 55 dB A Product Weight Product Weight 65 lbs 29 5 kg 66 1 lbs 30 kg Operating Temp Operating Temp 61 F 88 F 16 1 C 31 1 C 61 F 88...

Page 14: ...THIS WARRANTY C A Marketing Inc located at 114 Tived Lane East Edison NJ we extend this limited warranty only to the consumer who originally purchased the product you It does not extend to any subse...

Reviews: