Ivation IVAPAC12BTU User Manual Download Page 7

7

OPTIONAL SECURITY BRACKET INSTALLATION

CONTROL PANEL OVERVIEW

Your window kit also includes an optional security bracket that can be installed to prevent the window from being 
opened from the outside while the window kit is in place. 

To install the security bracket, fasten it to the window with a type B screw as shown, depending on the type of window.

1. 

POWER:

 Press the POWER button once to manually turn the portable air conditioner on. Press it again to turn 

 

the unit off. 

2. 

MODE:

 Press the MODE button to cycle through the different mode options. The corresponding indicator LEDs 

 

will then light up on the control panel. The available modes are as follows: Air Conditioning mode (

COOL

), Fan 

 Only 

mode 

(

FAN

), Dehumidifier mode (

DRY

), Sleep mode (

SLEEP

), and Auto mode (

AUTO

). 

 

NOTE: The exhaust hose and window kit must be installed in order to use the unit in air conditioner, dehumidifier, 

 

auto, and sleep modes. When using this device in fan-only mode, however, the window kit is not required.

3. 

TEMP:

 Set your desired temperature by pressing the 

+

 or 

 buttons while the unit is in air conditioning mode. 

 

The temperature indicator LED will flash the temperature while it is being adjusted, and then steadily display the 

 

temperature at which it is set until you change it. 

 

NOTE: The temperature will be displayed in degrees Fahrenheit. To switch between Fahrenheit and Celsius, press 

 

and hold the 

+

 and 

 buttons for three (3) seconds while the unit is plugged in but not powered on. 

4. 

FAN SPEED:

 Press the 

FAN SPEED

 button to cycle between the three fan speeds: high, medium, or low. The 

 

corresponding indicator LEDs will light up.

 

NOTE: When the unit is in dehumidifier mode, the fan speed cannot be changed; when Turbo Cool mode is activated, 

 

the fan speed will automatically be set on high and cannot be changed during that time.

Single/Double Hung Windows

Sliding Windows

Security bracket

Type B 
screw

Security 
bracket

Type B screw

Sleep Mode
Indicator

 

 

Fan Speed
Indicators

 

 

Auto Mode
Indicator

 

Air Conditioner 
Mode Indicator  

Fan Mode 
Indicator  

Power
Indicator

 

 

Bucket Full
Indicator

 

 

Turbo Cool
Indicator

 

 

Timer

Indicator

 

Dehumidifier 
Mode Indicator

 

 

5

2

3

4

6

1

Summary of Contents for IVAPAC12BTU

Page 1: ...product and retain this guide for reference This product is intended for domestic use only This product is covered by a limited one year warranty Coverage is subject to limits and exclusions See warr...

Page 2: ...R button or the TIMER function to turn this unit on or off Never use this unit in an area subject to excessive moisture or humidity or in the immediate surroundings of a bath shower swimming pool or s...

Page 3: ...button while the air conditioner is in operation 2 DO NOT use the TEST and RESET buttons as ON and OFF switches 3 The cord and plug are not intended to offer protection to externally connected loads o...

Page 4: ...Opening 8 Air Intake Grille 9 Condensation Drainage Hole WINDOW KIT 10 16 10 Exhaust Hose 11 Exhaust Hose Connector 12 Window Kit Adapter Grille 13 13a Window Kit Adapter 14 Optional Window Kit Adapte...

Page 5: ...installed in sliding windows and sliding glass doors up to 7 2 13 m long When installing the window kit make sure to keep the exhaust hose as short and straight as possible for maximum efficiency Asse...

Page 6: ...mark the kit and cut one end down to properly t the opening 2 Screw the exhaust hose connector 11 onto the exhaust hose 10 as shown 4 Attach the exhaust hose 10 to the window kit adapter 13 13a and th...

Page 7: ...s not required 3 TEMP Set your desired temperature by pressing the or buttons while the unit is in air conditioning mode The temperature indicator LED will ash the temperature while it is being adjust...

Page 8: ...t adjustable in this mode 7 BUCKET FULL When this air conditioner cannot evaporate the collected moisture fast enough the excess water collects in a backup water tank located inside the unit This wate...

Page 9: ...The hour indicator on the LCD screen will turn on Use the and buttons to set the duration of the timer in hours from 1 24 To cancel the timer press the TIMER button and hold it until the timer icon a...

Page 10: ...lectrical outlet 3 Press the POWER button to turn on the unit 4 Press the MODE button until the auto mode indicator AUTO lights up on the control panel display or the remote LCD screen Sleep Mode In s...

Page 11: ...the excess hose length 5 Make sure there are no kinks or knots in the garden hose as shown below 6 When you turn the air conditioner on gravity will help drain the water from the internal water tank...

Page 12: ...sport 1 Empty any excess water by unplugging the drain plug in the back of the unit as described on page 11 2 Unplug the unit 3 Store or transport the unit in a cool dry place TROUBLESHOOTING Problem...

Page 13: ...Power Source 115 V 60 Hz 115 V 60 Hz Noise Level Noise Level 55 dB A 55 dB A Product Weight Product Weight 65 lbs 29 5 kg 66 1 lbs 30 kg Operating Temp Operating Temp 61 F 88 F 16 1 C 31 1 C 61 F 88...

Page 14: ...THIS WARRANTY C A Marketing Inc located at 114 Tived Lane East Edison NJ we extend this limited warranty only to the consumer who originally purchased the product you It does not extend to any subse...

Reviews: