PerformaxEasyExPerformaxEasyExSpeed_UM_9752153010_NL_D_ GB_F_V2_2
55
GB
4 Technical specifications
Power Requirements
Supply Voltage
24 V DC nominal
Primary Fuse
0,5 AT, Type: 70-007-65/0.5A, Siba
This fuse has a rupturing capacity of min. 1500A (breaking capacity).
This fuse is present in the delivered Ex Status Module by Simco-Ion.
Current consumption
Max. 0,4 A DC
Connection
Cable 5 x 0,34 mm
2
Max. total cable length @ supply
24V DC ± 2%
24V DC ± 5%
24V DC ± 10%
Max. cable resistance per wire
3,125Ω
2,25Ω
0,75Ω
Standard Simco 5x0,34 mm
2
&
M12 Male-Female cable
62,5m
45m
15m
Input
Remote on/off
10 – 30 V DC nominal (Ri >10k)
Activation time
30 ms
Output
Output voltage emitters
Max. 9 kV positive and negative
Current per emitter to earth
Max. 50 µA
High voltage OK (HV OK)
Supply voltage -1 V, max. 50 mA
Environment
Usage
Industrial, indoor usage
Ex environment (See Chapter 3)
ATEX
II 2 GD
IECEx BAS 17.0095X
Ex mb IIB T4 Gb
Ex mb sb IIB T4 Gb
Ex mb IIIB T135°C Db
Ex mb sb IIIB T135°C Db
Protection class
IP66
Ambient temperature
0 - 40°C
Max. Temperature enclosure
135°C
Material (Speed)
Performax Easy Ex
0 – 500 m/min
Performax Easy Ex Speed
>500 m/min
Werking distance
Performax Easy Ex
Performax Easy Ex Speed
100 - 300 mm
50 – 300 mm
Local signaling
2-Colour LED
Continual:
Blinking:
Green
In use
Stand-by
Red
Overloaded
HV OK overloaded
See chapter 7 for more info
Mechanical
Effective length
Performax Easy Ex
270 - 2790 mm
in increments of 180 mm
Performax Easy Ex Speed
90 - 2790 mm
in increments of 60 mm
Dimensions exclusive
Mounting brackets
Tot. length=
Eff. 250 mm (with protective hose)
Tot. length=
Eff. 180 mm (without protective hose)
Width
30 mm
Height
52 mm
Weight
2,2 kg/m
Enclosure
Aluminium / PA6 / PUR
Universal Mounting brackets
PA66/6