5 Installation
Warning:
- Check before using the Performax Easy Ex (Speed) in an explosion hazardous zone, if
it is suitable for use in your explosion risk zone classification.
- Mount the Performax Easy Ex (Speed) in a manner that provides complete protection
against impact
- Only the Performax Easy Ex (Speed) with fixed wiring can be installed in the
hazardous area. The Ex Status Module and any other connected devices must be
mounted outside the Ex zone.
- Electrical installation and repairs must be done only by a skilled electrical engineer
and in accordance with all national and local regulations.
- When working on the equipment, the equipment must be disconnected from the power
supply.
- The equipment must be properly grounded. Earthing is necessary to ensure safe
operation and to prevent any electrical shock when touched.
- Connect the ground terminal on the anti-static bar to a grounded part of the machine
with a wire of a minimum size of 4mm
2
.
- Use the Performax Easy Ex (Speed) always in combination with the Ex Status Module.
See the list of spare parts for the available parts and accessories.
5.1 Simplified system overview
A Status Module is needed for each anti-static bar. The anti-static bar is connected to the Status
Module through the wires at a connector block in the Status Module. For instructions, see 5.8.2
The power supply for the anti-static bar is supplied via a connector from the Status Module. This
can be a desk top supply, a DIN-rail, or a 24V DC supply.
5.2 Check
- Make sure the equipment is undamaged and that the correct version is received.
- Make sure the packing slip corresponds with the data of the received product.
Should you have any problems and / or questions, please contact Simco-Ion or the local agent
in your area.
Image 5.1.1: System overview