5.6 Dissemble Performax Easy Ex (Speed) (slide bracket)
- Remove the connection cable from the Ex Status Module.
- Unscrew the set screw (No. 6) from the brackets (see Image 5).
- Slide the anti-static bar with brackets from the mounting feet, in the direction of the three
triangles till it stops, pull the anti-static bar perpendicular to the mounting feet.
5.7 Alternative brackets
As an alternative to the plastic brackets, 2 additional stainless steel types are available:
5.8 Connecting the Anti-static bar
Warning:
- Observe the warnings at the beginning of this chapter.
- The Ex Status Module must be mounted outside the Ex zone.
- Use the Performax Easy Ex (Speed) always in combination with the Ex Status Module.
Never connect the Performax Easy Ex (Speed) directly to the power supply, this is
because the Ex Status Module contains the required fuse (0,5 AT / 1500A breaking
capacity).
-
Use with the Performax Easy Ex (Speed) designed for use with protective hose, always
the hose and fixing materials indicated by Simco.
5.8.1 Connect safety earthing
Connect the anti-static bar with an M4 eyelet and a grounding wire of at least 4 mm² to a
grounded machine part or grounded terminal.
Image 5.8.1.1: Connecting grounding
Image 5.7.1: Bracket T-slot stainless steel
Image 5.7.2: Bracket thread M6x35 stainless steel