10. Then plug in high voltage connector on static bar to HV1 or HV2 on power
supply. Secure high voltage connector with the (2) captive screws on the sides
of the connector. Do not over-tighten.
CAUTION –
Shock Hazard
Do not connect static neutralizing bar with power supply energized. Disconnect
input power or switch power off before connecting static bar.
NOTE –
Failure to fully seat the high voltage connectors into the power supply
connectors may result in permanent damage to the bar, cable or power supply.
C.
Connect power supply alarm output
(if used). The power supply “Alarm Output”
is a standard DB25 pin connector located on the end of the IQ Power™ HL Power
Supply. A maximum distance of 3 meters [10 feet] or less is recommended.
Pin
Description
Pin
Description
1
Remote on/off optocoupler (-)
10
No connection
14
Remote on/off optocoupler (+)
6
No connection
19
No connection
2
Clean Bar Relay (common)*
11
Power Relay (common)*
3
Clean Bar Relay (norm close)*
7
Power Relay (normal closed)*
16
Clean Bar Relay (norm open)*
20
Power Relay (normally open)*
8
Fault Relay (common)*
4
Fault Relay (normally closed)*
12
Power in (ground)**
17
Fault Relay (normally open)*
24
Power in (ground)**
9
Bar On Relay (common)*
13
Power in (+24V
DC)**
5
Bar On Relay (normal closed)*
25
Power in (+)**
18
Bar On Relay (normally open)*
*30V 1A Rating on Contacts
**1.6A Rating
, Connect pins 12 & 24 in parallel and 13 & 25 in parallel