![ITW Simco-Ion IQ Power HL Installation And Operating Instructions Manual Download Page 17](http://html.mh-extra.com/html/itw/simco-ion-iq-power-hl/simco-ion-iq-power-hl_installation-and-operating-instructions-manual_2096737017.webp)
15
IQ Power™ HL
5201201 Rev. D
To adjust the power supply number, turn the unit on and wait for the LED self-test to
complete. The COMM light will briefly stay lit and the power supply number may
be adjusted at this time. Press and hold the Initial Calibration button until the power
supply number increments by one (5 second window). Subsequent presses of the Initial
Calibration button will increment the power supply numbers (5 second window). The
Ion Power station number will be displayed and the IQ Power™ / Performax IQ HL PS
address will “map” as shown on the Power Supply Number Table. The incrementing
“wraps around”. Stop pressing the Initial Calibration button when the desired power
supply numbers have been reached. Wait 5 seconds, the COMM light will go out and the
Speed and Distance LEDs will flicker, indicating the power supply numbers have been
saved.
To reset the unit to its factory default power supply numbers (see Power Supply Number
Table), press and hold the Initial Calibration button while turning the unit on. Continue
holding down the Initial Calibration button while the Output indicators “count-up” and
when the COMM light starts flashing, then release the Initial Calibration button. When
just the Speed and Distance LED flicker, the default power supply numbers (address = ”1”,
station number = ”30”) are saved.