12
IQ Power™ HL
5201201 Rev. D
6. OPERATION
NOTE –
Before switching on power supply; ensure that units are properly
grounded and that static bar & probes are properly installed.
Power Supply Indicators
Power:
Lights (green) to indicate power is on and the IQ Power™ HL Power Supply is
ready to operate.
Comm:
Lights (green) to indicate digital communication is established with an IQ
Power™ Communication Module or Control Station. The Comm light will flicker to
indicate communication activity.
Bar On:
Lights (green) to indicate when the static neutralizing bar is active.
Fault:
Lights (red) to indicate faulty condition of static bar, power supply or high voltage
connections. Power will have to be turned off to clear the fault. When fault is cleared and
power is restored, the fault light will be extinguished.
Clean Bar:
Lights (yellow) to indicate need to clean static bar. Clean Bar indicator may
light with low ion output (dirt build-up on ion emitters) or high output current (conductive
contamination on face of bar).
Mode:
The indicator next to the type of bar connected will light (green). “Speed” or
“Hybrid” will be indicated. In cases where two different types of bars are connected,
the system will set for the safer of the two operating voltages and light the corresponding
Mode indicator.
The Output indicators (along with the Mode indicators) also indicate the
power supply
number
during start-up of the power supply.
Output:
The output indicators range from “Low” to “High” in 10 steps
(2-red, 3-yellow, 5-green) and light to indicate the system relative ion output. The output
will normally be in the high range. Low output generally indicates the need to clean the
static bar.
Power Supply Operators
Calibrate:
Is a momentary push button switch located on the face label. Pressing the face
label firmly on “Calibrate” initiates the calibration sequence and sets the relative nominal
ion output for the system.
The Calibrate button is also used to change the
power supply number
. This number
is used in software to identify the power supply in systems that contain multiple power
supplies and include an optional Communication Module.